Technical Data
9.0
10
Parameter Setting
9.7
Flash Codes:
When a fault occurs, the output LED will begin to flash. There will be a long delay followed by a
number of flashes with a short delay.
Count the number of flashes, then find the corresponding
information in the table below.
Error Codes:
The Multi Switch maintains a fault log with fault counters. Each time a specific fault occurs, its
counter will be incremented by one. The fault log can be accessed by the configurator (Dealer-level
profile access). This user can clear one or all of the errors from the fault log.
In the case of error codes, please contact mo-Vis to learn about the required actions.
Should a problem persist after corrective action, please contact your local dealer or mo-Vis service
engineer.
Flash
Count:
Fault Reason
Required Action:
1
-
-
2
-
-
3
Power Supply
(voltage under or over)
Check power connections
4
Sensor
Replace printed circuit board (PCB)
5
-
-
6
ADC
(internal analog-to-digital converter)
Replace PCB
7
Failure of test flag or diagnostic
- Redo tests
- Replace PCB
8
CPU fault
Replace PCB
9
Scheduler fault
- Update Software
- Replace PCB
10
Coding error
Troubleshooting
9.6