1-4.It is acceptable to install other software as required. (i.e. RAIDGuide
monitoring software)
1-5.If the 2 hard-disks used are of different storage capacity, SR3610 will
automatically detect storage capacity, in case one’s capacity is larger than the
other, then it will base on the smaller one to assign storage space. This method
enables the computer to support the smallest hard-disk detected by SR3610.
2.
※
Steps for installing a new hard-disk and a used one.
In the event of installing one new hard-disk along with a used hard-disk, it is
advisable to select the new hard-disk to be same as the other in terms of brand,
specification, size and storage capacity. If this is not possible, the new one must be
updated specification as well as larger in storage capacity than the old one.
When the swappable hard-disks (including the new one) are in position, SR3610 is
able to perform automatic formatting and
data rebuilding
function, and duplicates
the data to the hard-disk that will be assigned as new.
2-1.When all power are turned off, first place the already used hard-disk in
swappable tray then insert it into the first HDD position of SR3610.
2-2. At the time power of SR3610 is turned on, LED indicator of “ALARM” will
glow in orginal and the buzzer will sound; on the LCD, it will display Pri
HDD: OK Sec HDD: OFF”.
2-3. At this time, insert the new hard-disk into the second HDD position of SR3610,
in about 10 to 15 seconds, SR3610 will automatically perform data rebuilding
and the progress could be seen on LCD screen.
2-4. Under the condition that PC is not saving or reading data with SR3610, it takes
about 20 minutes for a 40GB hard-disk and so forth.
-
15
-