Chapter 3
SR3610 Operation Guide
3-1 RAID Level set up
1. SR3610 is able to support RAID 1 mode or RAID 0 mode with RAID Subsystem.
Once RAID Level has been set up, any future changes might cause damage of the
stored data during the rebuilding process. Prior to confirming RAID level, please
consider each option’s respective application as whether the priority is data safety
(RAID 1) or storage space expansion capability (RAID 0)
2. RAID Level could be set up by press of buttons on the front panel. SR3610’s
default value is RAID 1. If RAID 0 is preferred, change could be made by pressing
the buttons on the front LCD control panel and follow the instruction displayed on the
screen.
Factory default value
.
Operation mode Switch RAID 1
§ Setting up RAID 1
.
Operation mode is set at RAID 1 (default)
※
1.Steps for installation of two new hard-disks
1-1.It is advisable to use 2 exactly the same hard-disks to achieve better
performance.
1-2.After all power have been turned off, place the 2 new hard-disks in the
swappable tray of SR3610, since the system has been internally programmed to
RAID 1, there is no need for new set up.
1-3.Using operation tool in the system’s control panel, assign appropriate drive to
the completed RAID hard-disk, then perform formatting and partition with disk
management software.
-
14
-