2.8.2.
Install and adjust the Micro-Switch assembly
1.
Clean the brake and remove glue from micro-switch installation surface.
2.
Smear some glue on micro-switch back surface, install micro-switch with plate, tighten bolt
M2
×
10(No.2) with the cross screwdriver wrench
(
6
×
125
)
, coated with TONSAN
1222 thread sealant. Wait about 6 hours until the glue solidifies.
3.
Micro-switch adjustment
:
Check
:
make sure that the gap between the static plate and the dynamic plate: 030-0.40mm.
(refer to IGL15 permanent magnet synchronous elevator tractor spare parts replacement
manual - brake FZD10 replacement and adjustment method)
Connect the stylus of multimeter with the exit wire of micro switch (NO, COM), and dial the
multimeter to the corresponding gear position. When the brake loses power and holds the
brake, insert the feeler into the gap A between the contact and lever position of the micro
switch. When the feeler is 0.65mm, the contact will not act (no display on the multimeter),
and when the feeler is 0.85mm, the contact will act (display and hoot on the multimeter). If
not, it needs to be adjusted.
Loosen the nut M5 with an open wrench (8mm), and screw out the bolt (M5×30) 1 ~ 2mm.
Apply a small amount of TONSAN 1243 thread glue to the screw hole and bolt joint surface.