EN
16
If "OK" is not shown over the "MR" button on the
display panel, then the torque wrench memory is full
(see Chapter "Memory is full", page 19).
If working through a define process, after finishing
adjusting parameters then the next adjusting
parameters within the define process will be
selected. This applies for all operating modes.
After the last adjusting parameters of the define
process the first adjusting parameters will be
automatically selected.
Peak value hold
In the "torque" mode the wrench automatically
remembers the peak value. This value is shown on the
display.
Create a new wrenching function and give it a name.
Set the tolerance value to zero and the pre-warning to
100%. All the other parameters can be taken over
from the pre-settings.
As long as the torque wrench is being operated, the
torque value shown will rise.
After completing the wrenching function, this torque
value will be retained.
WARNING
Danger of severe injuries due to
excessively tight threaded
connections.
If the red light-emitting diode lights up,
immediately abort the bolting process.
Exchange the bolt for a new bolt.