1.

 

INTRODUCTION 

This instruction sheet covers application, inspection and maintenance procedures for Hydraulic Crimping Head 
PN 1752786-1 shown in Figure 1. 

The crimping head accepts interchangeable die sets for a variety of terminals and splices for large wire sizes -
4/0 through 1000 MCM range.  Refer to the instructions packaged with the specific die sets for compatible 
products, wire ranges, strip dimensions, and application procedures.   

This crimping head is designed for use with Foot Hydraulic Pump PN 1583659-1, Hand Hydraulic Pump PN 
1583661-1, or Electric Hydraulic Pumps; PN 1804700-1 (115 VAC) and PN 1804700-2 (220 VAC). 
 

Warning

: To avoid personal injury and potential damage to the crimp head, TE Connectivity (TE) requires the 

crimp head to operate at 9,800 to 10,200 PSI [676 to 703 bar].  TE recommends using 10,000 PSI [689 bar] TE 

Hydraulic Pumps as other manufacturers’ pumps may apply insufficient pressure (resulting in an inadequate 

crimp) or excessive pressure (resulting in failure of the head).  Additionally, the TE pump must be used to 
maintain CE certification; if 

using other manufacturers’ pumps

, the user is responsible for self-certification. 

 
Read these instructions, and all applicable references before inserting any die set assemblies and crimping any 
terminals or splices. 
 

NOTE 

Dimensions in this instruction sheet are in millimeters [with inches in brackets]. Illustrations and figures are for reference only 
and are not drawn to scale.

 

 
Reasons for reissue of this Instruction Sheet are provided in Section 9; REVISION SUMMARY    