10
SLEEP OFF:
Setting duration of sleep time for the machine
(Duration = 10 min. -200 min.).
1.
When this function is OFF, the machine does not
enter dormancy state.
2.
If adjusted to 200, it means that in the standby
state, there is no timing fogging and continuous
fogging in 200 minutes, then enter the dormancy
state. Under the dormancy state, the heater is no
longer standby, and stops heating until cooling.
3.
In dormant state, if timing fogging or continuous
fogging is started again, the machine will start
heating again and enter the standby state.
FLUID SCAN ON/OFF:
ON/OFF setting of automatic inspection of fluid.
1.
When this function is OFF, the machine cannot
inspect volume of the fluid. This means that the
machine will keep working even there’s no fluid.
2.
When this function is ON, the machine starts this
inspection function automatically.
When the machine detects that no fluid will stop,
the LCD display will show “NO FLUID”.
Display Backlight Setting:
There are two modes.
Long pressing of the MENU can interchange these
two backlight modes.
1. Lighted mode:
display appears “— —STANDBY— —”.
2. Power saving mode:
display appears “—STANDBY— “.
Backlight lights up only when pressed.
Few minutes later light off automatically.