12
Operation
Pour enough clean water into water tank and water-based low-fog
fluid into smoke tank, please don’t overfill. Plug mains power cord
from the machine into appropriate power supply socket.
Primary power on, shows the current software version;
If there is no water or insufficient water, there will be
no water warning;
2 seconds after, switches to working status;
— —HEATING— —:
Heating up. Setting function value
is allowed when heating up.
F100:
Shows the smoke output value; On the left
shows the current smoke output is 100%.
W10:
Wind volume;On the left shows the current
wind volume is 10%.
U:ON:
Water Mist ON/OFF for AQUAFOG 2500;
On the left shows the current water mist is ON.
U:A+B:
Water Mist volume for AQUAFOG 3600; On the
left shows the current water mist is A+B (100%).
V1.0
NO WATER
— —HEATING— —
F100 W10 U:ON
— —HEATING— —
F100 W10 U:A+B
Continuous Fogging Operation ......................................................
Panel button control when DMX signals are not connected.
Press Function button, to select fog VAL and setting
the smoke output, press UP/DOWN button to adjust
the value of smoke output to 0% or 10~100%.
The display on left shows volume is 100%;
Press Function button, to select wind VAL and setting
the value of wind volume, press UP/DOWN button
to adjust the value of wind volume from 10~100%.
The display on left shows volume is 10%;
FOG VAL
100
WIND VAL
10
1.
2.
After the preheating is completed, please do the operation according to the
operating mode required below.