background image

25

Accessories

Fog Conducting Hose (2.8 meters)

Top cover of flight case

Fog Conducting Hose Adaptor

AQUAFOG HOSE SET ...........................................................

AQUAFOG CASE TOP ...........................................................

Summary of Contents for AQUAFOG 2500

Page 1: ...User manual ENGLISH AQUAFOG 2500 3600 Version 1 0 AQUAFOG 2500 AQUAFOG 3600...

Page 2: ...ion 26 CONTENTS If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Read the manual Indoor use only This s...

Page 3: ...wer supply for your unit See your product specification label for appropriate power supply This appliance must be earthed Disconnect from electric mains power supply when not in use when filling the w...

Page 4: ...hout user serviceable parts in the package please contact your local agent or qualified technician for servicing Without changeable structure by non qualified user please do not open the rear panel or...

Page 5: ...manual thoroughly before operation If any abnormal running occurs stop it immediately empty the fluid and bring the done up unit recommend original box to your agent or dealer for servicing Make sure...

Page 6: ...without any prior written notice Particular Warning The machine must keep enough water to be used normally Please do not exceed the warning water line when it is poured into the water When water is n...

Page 7: ...l water line F LCD display G 6 Function buttons H LED Indicator of Smoke ON OFF I Smoke ON OFF Express Output Button J DMX 5 PIN XLR Input K DMX 5 PIN XLR Output L DMX 3 PIN XLR Input M DMX 3 PIN XLR...

Page 8: ...machine packed in flight case Output by one button Additional express output button is designed to simplify the continuous fogging 5 8 minutes of first heating time 2 liter liquid tank Use of our wat...

Page 9: ...ecial low fog fluid Figure1 B 5 Fill the clean water to the tank Figure1 C Take care not to exceed the warning water line and ensure the use of clean water When water is not enough the machine will st...

Page 10: ...mation 5 pin XLR 3 pin XLR 1 Ground 1 Ground 1 Ground 1 Ground 2 Cold 2 Cold 2 Cold 2 Cold 3 Hot 3 Hot 3 Hot 3 Hot 4 N A 4 N A 5 N A 5 N A XLR Pin Configuration Pin 1 Ground Pin 2 Data Compliment nega...

Page 11: ...ress UP Down 1 5 seconds can change value continuously and fast pressed UP DOWN at the same time value back to 1 FOG VAL Setting of smoke output 0 10 100 WIND VAL Setting of wind volume 10 100 WATER M...

Page 12: ...ating again and enter the standby state FLUID SCAN ON OFF ON OFF setting of automatic inspection of fluid 1 When this function is OFF the machine cannot inspect volume of the fluid This means that the...

Page 13: ...machine that combines the effects of smoke and water mist the specific relationship is as follows smoke water mist low fog total volume Control priority order When both DMX console and VT 1 are conne...

Page 14: ...FF for AQUAFOG 2500 On the left shows the current water mist is ON U A B Water Mist volume for AQUAFOG 3600 On the left shows the current water mist is A B 100 V1 0 NO WATER HEATING F100 W10 U ON HEAT...

Page 15: ...g the blue led above SMOKE ON OFF BUTTON will continue to flash After several seconds return to left icon Press Function button to select water mist VAL and setting the state of volume press UP DOWN b...

Page 16: ...0 or 10 100 The display on left shows volume is 100 Press Function button to select water mist VAL and setting the state of volume press UP DOWN button to select the volume state ON OFF for AQUAFOG 2...

Page 17: ...This is to avoid causing negative effect when used next time After several seconds return to left icon CLEANING F100 D52 I30 STANDBY F100 W10 U A B 8 9 Set values are automatically saved UP DOWN butt...

Page 18: ...next time STANDBY F20 W50 U A B RUNNING F20 W50 U A B STANDBY F20 W50 U A B CLEANING F20 W50 U A B 5 7 9 8 6 The volume adjustment knob clockwise adjustment volume increases counterclockwise adjustme...

Page 19: ...press and hold Manual button without releasing Manual fogging operation can priority to other operations 3 Release Manual to recover previous status A B C D A 1 4 stereo jack B Knob C Green LED Volume...

Page 20: ...button to select the channel mode there are 1CH 4CH and 6CH to choose from set values are automatically saved Left display shows 6 channel mode Set values are automatically saved Then enter the DMX o...

Page 21: ...procedure to link more low fog machines if desired whole link is daisy chain 9 Done Refer to DMX channel chart in Figure 2 make related settings Now start operating Wig Smog with DMX console Set value...

Page 22: ...will always be cycled CH1 DMX Value Smoke ON OFF 6 255 ON 0 5 OFF CH1 CH2 CH3 CH4 DMX Value Smoke Volume DMX Value Wind Volume DMX Value Water Mist ON OFF DMX Value Smoke ON OFF 6 255 10 100 0 255 10...

Page 23: ...e Smoke ON OFF 6 255 ON 0 5 OFF CH1 CH2 CH3 CH4 DMX Value Smoke Volume DMX Value Wind Volume DMX Value Water Mist ON OFF DMX Value Smoke ON OFF 6 255 10 100 0 255 10 100 201 255 100 A B 128 255 ON 0 5...

Page 24: ...5 Check to see if there is enough clean water 6 Check whether there is low fog fluid 7 Whether the heater is in the heat light touch the iron plate next to the low fog fluid tank is lukewarm 8 Make su...

Page 25: ...e machine detects that no fluid the pump will stop working Maintenance Before doing maintenance please make sure that the power is cut the power cord is unplugged and the machine itself has cooled dow...

Page 26: ...clear all the liquid water and low fog fluid and keep the machine dry 6 Do not stack heavy objects or other items on the top of the machine to avoid damage or deformation of the machine 7 The machine...

Page 27: ...25 Accessories Fog Conducting Hose 2 8 meters Top cover of flight case Fog Conducting Hose Adaptor AQUAFOG HOSE SET AQUAFOG CASE TOP...

Page 28: ...Fogging Continuous Fogging Manual Fogging No Fluid Warning YES YES Low Water Shutdown YES YES Output Adjustment 0 10 100 0 10 100 Wind Adjustment 10 100 10 100 Water Mist Adjustment ON OF A 50 B 50 A...

Page 29: ...op cover of flight case Weight kg 72KG with top cover of flight case 57KG without top cover of flight case 75KG with top cover of flight case 60KG without top cover of flight case Accessories AQUAFOG...

Page 30: ...A Q U A F O G 2 5 0 0 A Q U A F O G 3 6 0 0 Save this instruction properly All the information is subject to change without prior notice...