15
INTELLIPRO
®
2 VST Variable Speed Pump Installation and User’s Guide
PRIMING
MENU
Pump Menu: Priming
Disabling Priming with an Automation
System
When the IntelliPro
®
2 VST Variable Speed Pump
is connected to an automation control system,
(IntelliTouch
®
, EasyTouch
®
or SunTouch
®
Control
Systems),
the priming feature on the pump
cannot be disabled by the external automation
control system only. It must also be disabled on
the pump itself.
If priming is enabled on start up, the pump responds to
its internal settings
before
responding to commands
from an automation control system.
If the pump is connected to an automation control
system and priming is not desired,
disable the
priming feature on both the pump and the
automation control system.
To disable priming with an automation system:
1. Disable the priming feature on the automation
control system at the load center or using an
IntelliTouch or EasyTouch system remote. (Refer
to the automation control system user’s guide for
additional information).
2. Temporarily disconnect the RS-485 communication
cable.
3. Open the lid to the control panel to disable
priming on the pump. Press
Menu
, use the arrow
buttons to scroll and select “Priming”, then select
“Disabled” (the factory default is set to “Enabled”).
Press
Escape
to exit the menu.
4. Once priming is disabled, reinstall the RS-485
communication cable.
Setting Priming Features
Note:
Priming features are only accessible if priming is
“Enabled”.
1. Press
Menu
.
2. Use
Down
arrow to scroll to “Priming” and press
Select.
3. The factory default is set to priming “Enabled“. To
disable, press
Select
.
4. Press
Save
if you have changed the setting - this will
save the selection.
5. Press
the
Down
arrow - the screen will read “Max
Priming Time”.
6. To change from factory default, press
Select.
The
cursor will highlight.
7. Use
the
Up
or
Down
arrows to change the time from
1 minute to 30 minutes.
8. Press
Save
to save.
9. Press
the
Down
arrow - the screen will read “Priming
Range”. Default is “5”.
10. Press
Select
to change the priming range. The cursor
will highlight the number.
11. Use the
Up
or
Down
arrows to change from 1 to 10.
Increasing the number allows the drive to detect prime
with less water flow.
12. Press
Save
to save.
13. Press the
Down
arrow - the screen will read “Priming
Delay”. Default is 20 seconds.
14. Press
Select
to change the priming delay time.
15. Use the
Up
or
Down
arrows to change from 1 second
to 10 minutes.
CAUTION:
Increasing the time causes the pump to
stay in the priming mode longer.
P
1. Disable priming on automation control system.
2. Disconnect the RS-485 communication cable.
3. Disable priming on pump.
4. Reinstall the RS-485 communication cable.