10
INTELLIPRO
®
2 VST Variable Speed Pump Installation and User’s Guide
Pump Menu: Speeds 1-8
SPEED 1-8
MENU
Pump Operating Modes
The IntelliPro
®
2 VST Variable Speed Pump can be
programmed in three different modes:
Manual, Schedule, and Egg Timer
. Speeds 1-4 can
be programmed in all three modes. Speeds 5-8 can
only be programmed in Schedule mode since there are
no buttons on the control panel for Speeds 5-8. The
default setting for Speeds 5-8 is “Disabled”.
Speed 1 (1-4)
Manual
Schedule
Egg Timer
Set Speed - Defa
Set Speed
Set Start Time
Set Stop Time
Set Speed
Time
Speed 5 (5-8)
Schedule
Set Speed
Set Start Time
Set Stop Time
Disabled
Default: Disabled
Manual
Assigns a speed to one of the four Speed buttons
on the control panel. This mode can only be used for
speeds 1-4. Speeds 1 and 2 are Manual by default.
To operate in Manual mode, press one of the four
speed buttons and then press the
Start/Stop
button.
The pump will run the assigned speed for that speed
button.
Egg Timer
Speeds 1-4 can be programmed to run for a duration
of time once a speed button is pressed.
Speeds 3 and 4 are Egg Timers by default. This
prevents the pump from running at a speed higher
than half of the maximum speed indefinitely. If you
desire a different method of operation, speeds 3 and 4
can be changed to Manual mode in the control menu.
To operate in Egg Timer mode, press a speed
button and then press
Start/Stop
. The pump will run
that speed for the set amount of time and then turn off.
Schedule
Program speeds 1-8 start and stop at a specific time
during a 24 hour period. Speeds programmed in
Schedule mode will override any manually selected
speed once the next Schedule command commences.
Speed Menu Tree Options
Entering Password
1. Press any button (besides the speed button) to
prompt the screen for a password.
2. To enter password, use the
Left
and
Right
arrows to
move the cursor and the
Up
and
Down
arrow button
to scroll through the digit then press
Save
to confirm.
Setting Password
1. Check that the green power LED is on.
2. Press
Menu
. Press
Select
to select “Settings”.
3. Use
the
Up
or
Down
arrow to scroll to “Device”.
4. Press
Select.
5. Press
Up
or
Down
arrow to scroll to “Password”. The
default setting is “Disabled”.
6. Press
Select.
7. Press
Up
or
Down
arrow to change the setting to
“Enabled”. Press
Save
to save.
8. Press
the
Down
arrow. “Password Timeout” will be
displayed. The factory default time is 1 minute. This
means the pump will go into Password Protection
mode 1 minute after the last control panel key is
pressed.
9. Press
Select
to change time setting from 1 minute
to 6 hours and press
Save
to save.
10. Press the
Down
arrow and then press
Select
on
“Enter Password” to change the setting.
11. Press the
Left
or
Right
arrows to move cursor and
press
the
Up
or
Down
arrow to change the password
number to desired setting.
12. Press
Save
to save. To cancel any changes, press
Back
to exit without saving.
MENU
SETTINGS
Pump Menu: Settings