13
INTELLIPRO
®
2 VST Variable Speed Pump Installation and User’s Guide
Pump Menu: Features
FEATURES
MENU
Quick Clean
This feature can be used to increase the pump speed for
vacuuming, cleaning, adding chemicals, after a storm for
extra skimming capability.
Press the
Quick Clean
button (LED on) and then
Start/Stop
to start. When the Quick Clean cycle is over,
the pump will resume regular schedules and be in
“Schedule” mode.
To access the Quick Clean menu:
1. Check that the green power LED is on and the
pump is stopped.
2. Press
Menu
.
3. Use
Up
or
Down
arrows to scroll to “Features”,
then press
Select
.
4. Press
the
Down
arrow and press
Select
for
“Quick Clean”.
5. Press
Select
to choose “Set Speed”.
6. Press
Select
to highlight the “RPM” first (ones)
column and change the speed.
7. Use
Up
or
Down
arrows to change the speed.
8. Press
Save
to save the speed.
9. Press
the
Down
arrow again, and press
Select
for “Time Duration”.
Time Out
The
Time Out feature keeps the pump from running it’s
programmed speeds for a set duration adjustable in the
menu.
The Time Out feature is displayed in hours and
minutes (Hrs:Mins).
Once Time Out is finished, the pump will return to its
previous mode of operation, the Start/Stop LED will be lit
and ready to turn on at the next scheduled run time.
To access the Time Out menu:
1. Check that the green power LED is on.
2. Press
Menu
.
3. Use
Up
or
Down
arrows to scroll to “Features”, then
press
Select
.
4. Press
Select
to choose “Timeout”.
5. Then
press
Select
again to choose “Timeout Duration”.
6. Press
Select
to change the time. The cursor will
highlight the minutes column.
7. Press
the
Left
arrow to move cursor to the hours
column.
Time out can be set from 1 minute to 10
hours.
8. Press
Save
to save the setting.
Note:
To cancel any changes, press
Back
to exit
without saving.
9. Press
Back
to exit the menu.
PRIMING
MENU
Pump Menu: Priming
The default setting for Priming is ENABLED. This
setting allows the pump to automatically detect if it is
primed for startup.
The priming feature increases the pump speed to
1800 RPM and pauses for three (3) seconds. If there is
sufficient water flow in the pump basket, the pump will
go out of priming mode and run its commanded speed.
If the water flow is not sufficient, as determined by the
Priming Range setting, the pump speed will increase to
the “Priming Speed” setting and remain for the priming
delay time (default 20 seconds). If there is sufficient
water flow in the pump basket at this time, it will exit
priming mode and transition to the commanded speed.
If there is still insufficient flow in the pump basket, the
pump will try to prime at the “Priming Speed” for the
amount of time set in the “Maximum Priming Time”
menu. Once the pump achieves prime, it will resume
normal operation after the preset priming delay.
Display during priming
12:15p
1800 RPM
T 00:01 460 WATTS
Priming
10. Press
Select
to change the time. The cursor will
highlight the minutes column.
11. Use
Up
or
Down
arrows to change the time
from 1 minute to 10 hours.
12. Press
Save
to save the time.
13. Press
Back
to exit the menu.
Note:
It is possible to set
“
Maximum Speed” too low
for the pump to properly prime. Maximum Speed
will limit Priming Speed, except in one case. If the
Maximum Speed is set below the lowest available
Priming Speed (2400 RPM) then the pump will exceed
the Maximum Speed while the priming feature is
running. This prevents the pump from having trouble
priming if the Maximum Speed is set this low. If this
is a problem, priming can be disabled in the Priming
Menu.