Programming manual
L6472
46/70
DocID022729 Rev 5
9.1.13 TOFF_MIN
The TOFF_MIN register contains the minimum OFF time value used by the current control
system (see
for details).
The available range for both parameters is from 0.5 µs to 64 µs.
Any attempt to write to the register when the motor is running causes the command to be
ignored and NOTPERF_CMD to rise (see
9.1.14 ADC_OUT
The ADC_OUT register contains the result of the analog-to-digital conversion of the ADCIN
pin voltage.
Any attempt to write to the register causes the command to be ignored and the
NOTPERF_CMD flag to rise (see
Table 16. Minimum OFF time
TOFF_MIN [6 … 0]
Time
0 0 0 0 0 0 0
0.5
µs
0 0 0 0 0 0 1
1
µs
…
…
…
…
…
…
…
…
1 1 1 1 1 1 0
63.5
µs
1 1 1 1 1 1 1
64
µs
Table 17. ADC_OUT value and torque regulation feature
VADCIN/ VREG
ADC_OUT [4.0]
Output current amplitude
0
0 0 0 0 0
125
mA
1/32
0 0 0 0 1
250
mA
…
…
…
…
…
…
…
30/32
1 1 1 1 0
3.875
A
31/32
1 1 1 1 1
4
A