- FOR USE IN THE U.S. AND CANADA
- MOBILE HOME APPROVED
- CHECK WITH LOCAL AUTHORITIES AND OBTAIN NEEDED PERMITS. OBTAIN
FINAL INSPECTION FROM LOCAL BUILDING OFFICIALS.
- WE RECOMMEND INSTALLATION BY A QUALIFIED PROFESSIONAL OR
DEALER.
- ADHERE TO ALL CLEARANCES SPECIFIED BY THE MANUFACTURER OF THE
VENTING SYSTEM USED.
-
ADHERE TO ALL CLEARANCES SPECIFIED IN THE INSTALLATION
INSTRUCTIONS OF THIS STOVE.
- THIS STOVE USES A POSITIVE PRESSURE VENTING SYSTEM. DO NOT
INSTALL A FLUE DAMPER IN THE EXHAUST SYSTEM OF UNIT.
- DO NOT CONNECT THIS STOVE TO A CHIMNEY SYSTEM THAT IS
CONNECTED TO ANOTHER APPLIANCE.
- DO NOT INSTALL THIS UNIT IN A SLEEPING ROOM.
- INSTALL A SMOKE DETECTOR IN PROXIMITY OF THE STOVE.
- INSTALL A CARBON MONOXIDE DETECTOR IN PROXIMITY OF THE STOVE
ATTENTION
- CONDENSATION
:
When planning the installation of your Stove, keep in mind that
condensation is detrimental to exhaust systems. Install the Stove with a minimum of the
vent system exposed to the cold temperatures outside the envelope of the house.
- BATTERY BACKUP: St Croix does not offer battery backups. They are available online
if you decide to use one. Battery backup systems are useful if the Stove is installed using
horizontal venting only. This prevents any smoke from entering your home in the event of a
power failure.
- OPTIONAL EXHAUST FAN RELAY KIT: With optional relay kit 80P54232 installed in
the stove and connected to an inexpensive UPS battery backup (not part of the kit) you will
have maximum protection against smoke leaking out of the stove in the event of a power
failure. This is considered the best installation when venting horizontally. Contact your
dealer for more information.
1.
All joints of PL vent and single wall stainless steel pipe should be fastened by at least 3
screws and correctly installed. (Follow vent manufacturer’s instructions). Seal all joints with
high temperature silicone to create an airtight seal.