Ashby-MF Insert
46
5.
Exhaust System.
See Figure 27, 28 and 29 for information on cleaning fly ash that
collects in the vent system. Periodic cleaning of the exhaust system is required. Under
certain conditions chimneys may plug up rapidly. Dirty/High moisture content Corn,
Wheat, Rye Cherry Pits or Distiller’s Grain require more frequent chimney cleanings.
The products of combustion will also contain small particles of fly ash. The fly ash will
collect in the exhaust vent and restrict the flow of the flue gases. Ask the dealer for
suggested frequency of cleaning, equipment needed and procedures for cleaning. Check
the Exhaust system at least once every two months during the heating season to check the
amount of ash that accumulates in the elbows or tee’s of the exhaust system to determine
the frequency of cleaning.
See Page 25 “Preventing Chimney Fires”
.
6.
Gaskets.
Periodically inspect the condition of the rope gasket around the door, window
and ash door. Replace as needed.
Yearly Maintenance
Many dealers offer a Service Contract that will cover Yearly Maintenance. Contact your St.
Croix Dealer for assistance in maintaining your Ashby in top condition. Yearly maintenance is
designed to assure safe operation, prolong the life of the Ashby and help preserve its aesthetic
appeal.
1.
Spring Shutdown.
After the last burn in the spring let the unit cool down. Remove all
fuel from the hopper and the auger. Thoroughly clean the burn pot, burn pot box, ash pan
and ash traps behind the ash pan. (To locate the ash traps see figure 27 on page 44)
2. The Exhaust System should be thoroughly cleaned at least annually. Call your dealer for
this service. (See figure 30 on the following page)
3.
The Motor/Fan area behind the firebox and under the hopper should be vacuumed
annually. (See figure 30 on the following page)
NOTE: UNPLUG THE INSERT
. Remove the Surround panels of the Ashby-MF and pull the
unit from the fireplace. Carefully clean or vacuum any dust, cobwebs and household dust.
Carefully vacuum around the fan motors. If electrical wires become disconnected call your
dealer for service.
4.
The exhaust fan should be removed and cleaned with compressed air annually. Call
dealer for this service. Annual oiling of the motors is not needed. (See figure 30 on the
following page)
5.
The Convection fans should be removed and cleaned with compressed air annually. (See
figure 30 on the following page)
6.
Replace the Door Gaskets if needed.
7.
Replace the Ash Pan Door gaskets if needed.
8.
Replace the Hopper Lid Gaskets if needed.