11
on sooner (or later), this value can
be altered by adjusting the potentio-
meter.
Light detection range adjustable
from approx. 5 - 300 lux.
Potentiometer turned clockwise:
light comes on earlier in the eve-
ning; anticlockwise: later.
Service switch (c)
OFF: for trouble-free setting of
threshold-value
ON: for normal operation
(after setting of threshold-value)
13 Setting the illumination peri-
od:
Warning
After application of the operating
voltage, the system requires approx.
2 min. to warm up. Wait this long
before altering the operating time. It
can be adjusted from approx. 10
sec. to 10 min. Turn the potentio-
meter clockwise to extend the illu-
mination period.
Technical data
• Max. Mounting range approx.
12 m (13,1 yds.), depending on the
height of installation, the optical
setting outdoor temperature and
the direction of approach
• Monitored area in immediate
vicinity from 6 m (6.6 yds.) to 1 m
(1.1 yds).
• Horizontal monitoring angle max.
110°, variable with mask attache-
ments included, asymmetrically 75°,
symmetrically 40°.
• Switch outputs
output 1: photoelectric lighting con-
troller
output 2: movement sensor
output 3: 1 and 2 wired in series
Switching capacity of all outputs
24 V/ 2A, floating
• Operating time for output 2 and 3
adjustable from approx. 10 sec to
10 minutes
• Threshold of light detection
adjust-able from approx- 5 - 300
Lux
• Self-lighting protection on output
3, i.e. the light source during the
operating time has no effect on the
photoelectric lighting controller
• Putting service switch into use
• Technical data:
operating voltage 12 V AC
operating current approx. 230 mA
bias current approx. 55 mA
temperature range -20° / + 50° C
(68° - 122° F)
weight 0.25 Kg
dimension 93 x 93 x 46
Cause
Solution
Powerful heat sources
shorten range
(cars, etc.)
Constant movement
Reduce horizontally
in monitored area
monitored area
Light source is directly in
Change angle of lens of
front photoelectric lighting
photoelectric lighting
controller (heat-change)
controller or point light
source elsewhere
Direct sunlight
Change angle of lens
Supply wires
Solution check
Power supply
Check
≥
11 V
Load circuits
Check
Fault
Excessive range
Light will not
switch off
Light continuous-
ly switches on
Light will not
switch on
Possible sources of problems