6. Control
Indication LEDs
green
- it is blinking at one-second interval when the devise is turned on and the
program is running
yellow
- indicates the presence of hot material
red
- lights in case of malfunction (and during startup):
- motor failure (motor is not running at correct speed – also during startup)
- temperature inside the sensor exceeds 60 ° C
Display - main menu
Use buttons
[←]
and
[→]
to display measured values and the current setting (not for setting):
Int= 75%
current infrared signal intensity
Pos= 50%
current position of the material (in operation mode LS - Loop Scanner)
A1=I16.0
Analog1 output – current value in mA (selected I = intensity)
A2=P12.0
Analog2 output – current value in mA (selected P = position)
Set=Rel1
selected set of gain and threshold (Rel/Man, set 1/2)
Gain 25%
selected gain
Thre 25%
selected threshold
Mode LS
selected operation mode of the sensor (LS or HMD)
Laser= 0
press button
[
↲
]
to light up the targeting laser for 2 minutes (
Laser= 1
)
Failure message can be flashing on the display (while the red LED is on and alarm output
signal drops to 0) in case of malfunction:
Alarm!!! Mot= Err
motor failure
Alarm!!! Tem=60°C
inside temperature exceeds 60°C
Or warning can be displayed during remote test:
Warning! ExtTest!
during remote TEST
(devise act as it is detecting material:
- analog outputs have 12 mA
- yellow LED is lighting, output signal material detect is on and
relay is closed)
You can confirm message by button.
[
↲
]
and continue to main menu. You can show message
again by pressing button
[ ↑ ]
. After automatic logout from the menu the message appears
automatically again.
Pressing button [
↲
] on any main menu item (except Laser = 0), you can login and change the
settings – but this is PIN protected.
Re-pressing of [
↲
] you are prompted to enter the PIN.