6. Control 

Indication LEDs 

 

green 

 

- it is blinking at one-second interval when the devise is turned on and the 
program is running  

 

yellow

  

- indicates the presence of hot material

 

red 

 

- lights in case of malfunction (and during startup):

 

- motor failure (motor is not running at correct speed – also during startup) 
- temperature inside the sensor exceeds 60 ° C  
 

Display - main menu 

 
Use buttons 

[←]

 and 

[→] 

to display measured values and the current setting (not for setting): 

 

Int= 75%

 

 

current infrared signal intensity 

 

Pos= 50%

 

 

current position of the material (in operation mode LS - Loop Scanner)

 

A1=I16.0

 

 

Analog1 output – current value in mA (selected I = intensity)

 

A2=P12.0

 

 

Analog2 output – current value in mA (selected P = position)

 

Set=Rel1

 

 

selected set of gain and threshold (Rel/Man, set 1/2)

 

Gain 25%

 

 

selected gain

 

Thre 25%

 

 

selected threshold

 

Mode  LS

 

 

selected operation mode of the sensor (LS or HMD)

 

Laser= 0

 

 

press button 

[

to light up the targeting laser for 2 minutes (

Laser= 1

)

 

 
Failure message can be flashing on the display (while the red LED is on and alarm output 
signal drops to 0) in case of malfunction: 

 
Alarm!!! Mot= Err 

motor failure

 

Alarm!!! Tem=60°C 

inside temperature exceeds 60°C 

  

Or warning can be displayed during remote test: 
 

Warning! ExtTest!   

during remote TEST

 

 

 

 

 

(devise act as it is detecting material:  

- analog outputs have 12 mA 
- yellow LED is lighting, output signal material detect is on and 

relay is closed) 

 

You can confirm message by button.

[

]

 and continue to main menu. You can show message 

again by pressing button 

[ ↑ ]

.  After automatic logout from the menu the message appears 

automatically again.   
 

 

 

Pressing button [

] on any main menu item (except Laser = 0), you can login and change the 

settings – but this is PIN protected. 
 
Re-pressing of [

] you are prompted to enter the PIN.  

Summary of Contents for SDIS - 1050

Page 1: ...USER MANUAL Universal position sensor and hot metal detector SDIS 1050...

Page 2: ...so that the infrared radiation is reflected to the photocell from each facet of rotating mirror very accurate even in the case when the entire sensing field is covered with hot material Radiation rec...

Page 3: ...ing made of aluminum alloy suport wall with mounting stand adjustable in both directions adapted to the cooling unit with water and blowing air windscreen to prevent pollution connection of water and...

Page 4: ...ndicular to the measured product When selecting the location of the sensor attention to the following must be paid Other source of infrared radiation in addition to the measured material can not inter...

Page 5: ...onnecting the cooling water and air and setting changes the sensor mounting 4 4 1 Cooling The cooling channel housing is positioned allowing the cooling water sensor Conditions for cooling The sensor...

Page 6: ...ron etc The temperature range depends on the infrared radiation of the product Angles standard sensor is supplied with a viewing angle of 50 degrees with a special mask inside the aperture angle can b...

Page 7: ...Operating temperature 10 C to 60 C At an ambient temperature above 40 C it is recommended to cool sensor with industrial water at a temperature up to 25 C pressure of 1 2 bar flow rate of 1 2 l min P...

Page 8: ......

Page 9: ...selected gain Thre 25 selected threshold Mode LS selected operation mode of the sensor LS or HMD Laser 0 press button to light up the targeting laser for 2 minutes Laser 1 Failure message can be flas...

Page 10: ...Set Rel Rel value set is chosen by external relay Man1 measure according ValSet1 Man2 measure according ValSet2 Window Beg 5 beginning of measuring window analog output 4mA position 0 End 95 ending o...

Page 11: ...s setting End 0 90 distance between laser to end of meas window meters Outputs AnOut1 I output signal Analog 1 I intensity P position setting of analog AnOut2 P output signal Analog 2 I intensity P po...

Page 12: ...detection is proportional to material position in the sensor s field of view Additionally sensor can be set to HMD mode hot metal detector sensor only detects if signal from PbS photocell exceeds thr...

Page 13: ...ilters of output signals to improve accuracy or to avoid false detection By adjusting SiUp and SiDo values you can specify how many times signal must be detected befor output detection signal is set o...

Page 14: ...sh pull C gray presence of material detect 24VDC max 50mA H ping neg presence of material detect 0VDC max 50mA M black neg alarm all OK 24VDC max 50mA alarm 0VDC Relay outputs E brown thick w presence...

Reviews: