SSK SDIS - 1050 User Manual Download Page 6

5. Technical specification 
  

5.1. Mechanical 
 

 

Weight: 4 kg 

 

Adjustable stand with mounting hole dia. 18 mm 

 

Dimensions: see drawing 

 

 
5.2. Optical

 

 

 

Spectral sensitivity: PbS photocell, range 1-3 micron with a maximum response at 2.2 

micron 

 

Temperature range of materials: depends on the material to be scanned: 

-

 

For iron and steel from 250 ° C when set to high sensitivity. If it is expected 

higher product temperature than 400 ° C, it is not appropriate to set a high sensitivity, 
because he could detect scale or reflections. 
-

 

For other materials, such as copper, bronze, cast iron, etc. The temperature range 

depends on the infrared radiation of the product. 
 

 

Angles - standard sensor is supplied with a viewing angle of 50 degrees, with a special 

mask inside the aperture angle can be reduced to 30 respectively. 10 degrees. Side angle or width 
of the scanned field - 3 degrees max 
 

 
5.3. Electrical 

 

 

Power: 

-

 

Voltage:                      24V DC 

-

 

Power consumption:  12 VA 

 

 

Signal the presence of the product: 
-

 

Semiconductor: complementary push-pull outputs 0/24VDC 50 mA 

-

 

Relay: single-pole switch: 

- switching capacity: 250V, 5A max 
- closing time: 10 ms 
- opening time: 5 ms 

 

 

"Alarm": push-pull output 0/24VDC 50 mA 

-   0V DC power failure, internal temperature or motor speed fault detection

 

-   24 V DC if no error is detected 
 

 

Analog signals 4-20 mA 
-

 

position of the material 

-

 

signal intensity 

 

 
 

Summary of Contents for SDIS - 1050

Page 1: ...USER MANUAL Universal position sensor and hot metal detector SDIS 1050...

Page 2: ...so that the infrared radiation is reflected to the photocell from each facet of rotating mirror very accurate even in the case when the entire sensing field is covered with hot material Radiation rec...

Page 3: ...ing made of aluminum alloy suport wall with mounting stand adjustable in both directions adapted to the cooling unit with water and blowing air windscreen to prevent pollution connection of water and...

Page 4: ...ndicular to the measured product When selecting the location of the sensor attention to the following must be paid Other source of infrared radiation in addition to the measured material can not inter...

Page 5: ...onnecting the cooling water and air and setting changes the sensor mounting 4 4 1 Cooling The cooling channel housing is positioned allowing the cooling water sensor Conditions for cooling The sensor...

Page 6: ...ron etc The temperature range depends on the infrared radiation of the product Angles standard sensor is supplied with a viewing angle of 50 degrees with a special mask inside the aperture angle can b...

Page 7: ...Operating temperature 10 C to 60 C At an ambient temperature above 40 C it is recommended to cool sensor with industrial water at a temperature up to 25 C pressure of 1 2 bar flow rate of 1 2 l min P...

Page 8: ......

Page 9: ...selected gain Thre 25 selected threshold Mode LS selected operation mode of the sensor LS or HMD Laser 0 press button to light up the targeting laser for 2 minutes Laser 1 Failure message can be flas...

Page 10: ...Set Rel Rel value set is chosen by external relay Man1 measure according ValSet1 Man2 measure according ValSet2 Window Beg 5 beginning of measuring window analog output 4mA position 0 End 95 ending o...

Page 11: ...s setting End 0 90 distance between laser to end of meas window meters Outputs AnOut1 I output signal Analog 1 I intensity P position setting of analog AnOut2 P output signal Analog 2 I intensity P po...

Page 12: ...detection is proportional to material position in the sensor s field of view Additionally sensor can be set to HMD mode hot metal detector sensor only detects if signal from PbS photocell exceeds thr...

Page 13: ...ilters of output signals to improve accuracy or to avoid false detection By adjusting SiUp and SiDo values you can specify how many times signal must be detected befor output detection signal is set o...

Page 14: ...sh pull C gray presence of material detect 24VDC max 50mA H ping neg presence of material detect 0VDC max 50mA M black neg alarm all OK 24VDC max 50mA alarm 0VDC Relay outputs E brown thick w presence...

Reviews: