SSK SDIS - 1050 User Manual Download Page 11

 
 
 
Sensor  

-> 

ValSet1 

-> 

Gain 25%

 

gain

 

detection setting 

(value set 1)   

Thre 25% 

switching threshold 

 

 

 

 

 

 

HysT 10% 

hysteresis of switching threshold 

 
 

 

 

ValSet2 

-> 

Gain 75%

 

gain 

(value set 2)   

Thre 50% 

switching threshold 

 

 

 

 

 

 

HysT 10% 

hysteresis of switching threshold 

 

Set=Rel 

 

Rel – setting set by relay status

 

Man1 - measure according ValSet1 
Man2 - measure according ValSet2 

 

 

Window 

 

-> 

Beg   5% 

beginning of measuring window (analog output =  4mA, 

                                                           position 0%)

 

End  95% 

ending of measuring window (analog output = 20mA, 
position 100%) 

 

 

 

HysB  5% 

hysteresis at the start of measuring window 

 

 

 

HysE  5% 

hysteresis at the end of measuring window 

 

Distance 

-> 

Mat 2.00 

distance between device to material (meters)

 

alternat. window 

Beg 0.90 

distance between laser to begin. of meas. window (meters) 

setting  

 

End 0.90 

distance between laser to end. of meas. window (meters) 

 

Outputs 

-> 

AnOut1 I 

output signal Analog 1 (I=intensity, P=position) 

 

setting of analog 

AnOut2 P 

output signal Analog 2 (I= intensity, P=position) 

output   

 

NoMatOut 

-> 

A1   4.0 

Analog1 value without material 

 

 

 

 

 

 

A2  last 

Analog2 value without material 

 
Filters  

-> 

SiUp  0 

detection signal filter – switching on after set amount  
pulses (in miliseconds)

 

 

 

 

SiDo  0 

detection signal filter – switching off after set amount  
pulses (in miliseconds) 

Pos      6 

filter of analog position signal-moving average for x ms 
(best choice is multiples of 6 – average for 1 mirror 
rotation)

 

 
Tests   

-> 

Laser= 0 

laser pointer (0 off, 1 on)

 

 

 

 

Lamp= R0 

testing by IRLED (R0/R1 according relay, M0 off, M1 on) 

 

 

 

Signal - 

detection test (- from photocell signal, 0 off, 1 on)

 

 

 

 

An1  -.- 

test Analog1 (-.- from photocell, on set value in mA)

 

 

 

 

An2  -.- 

test Analog2 (-.- from photocell, on set value in mA) 

 

 

 

 

Note:    

All tests are canceled after exit from Tests menu

 

 
 
 

Summary of Contents for SDIS - 1050

Page 1: ...USER MANUAL Universal position sensor and hot metal detector SDIS 1050...

Page 2: ...so that the infrared radiation is reflected to the photocell from each facet of rotating mirror very accurate even in the case when the entire sensing field is covered with hot material Radiation rec...

Page 3: ...ing made of aluminum alloy suport wall with mounting stand adjustable in both directions adapted to the cooling unit with water and blowing air windscreen to prevent pollution connection of water and...

Page 4: ...ndicular to the measured product When selecting the location of the sensor attention to the following must be paid Other source of infrared radiation in addition to the measured material can not inter...

Page 5: ...onnecting the cooling water and air and setting changes the sensor mounting 4 4 1 Cooling The cooling channel housing is positioned allowing the cooling water sensor Conditions for cooling The sensor...

Page 6: ...ron etc The temperature range depends on the infrared radiation of the product Angles standard sensor is supplied with a viewing angle of 50 degrees with a special mask inside the aperture angle can b...

Page 7: ...Operating temperature 10 C to 60 C At an ambient temperature above 40 C it is recommended to cool sensor with industrial water at a temperature up to 25 C pressure of 1 2 bar flow rate of 1 2 l min P...

Page 8: ......

Page 9: ...selected gain Thre 25 selected threshold Mode LS selected operation mode of the sensor LS or HMD Laser 0 press button to light up the targeting laser for 2 minutes Laser 1 Failure message can be flas...

Page 10: ...Set Rel Rel value set is chosen by external relay Man1 measure according ValSet1 Man2 measure according ValSet2 Window Beg 5 beginning of measuring window analog output 4mA position 0 End 95 ending o...

Page 11: ...s setting End 0 90 distance between laser to end of meas window meters Outputs AnOut1 I output signal Analog 1 I intensity P position setting of analog AnOut2 P output signal Analog 2 I intensity P po...

Page 12: ...detection is proportional to material position in the sensor s field of view Additionally sensor can be set to HMD mode hot metal detector sensor only detects if signal from PbS photocell exceeds thr...

Page 13: ...ilters of output signals to improve accuracy or to avoid false detection By adjusting SiUp and SiDo values you can specify how many times signal must be detected befor output detection signal is set o...

Page 14: ...sh pull C gray presence of material detect 24VDC max 50mA H ping neg presence of material detect 0VDC max 50mA M black neg alarm all OK 24VDC max 50mA alarm 0VDC Relay outputs E brown thick w presence...

Reviews: