 - hot metal detector - a device only detects the exceeding signal amplitude of photocells 

over the set threshold. It does not matter if the field of view of the sensor is an edge of the 
material. It is necessary to limit field of view (depending on site conditions) by the appropriate 
mechanical shutters or cover. (The basic limitation of the field of view is done by shield inside 
the sensor - max viewing angle is necessary to specify when ordering). 
 
 

3.  General description 

 
SDIS is a standalone sensor, heavy duty and easy to assembly and commissioning. 
Its basic features are: 

3.1 

Mechanical

:

 

 

 

hermetically sealed, accurately machined housing made of aluminum alloy. 

 

suport wall with mounting stand, adjustable in both directions, adapted to the cooling 

unit with water and blowing air windscreen to prevent pollution. 

 

connection of water and air in the supporting wall - when necessary the sensor can be 

easily replaced without disconnecting water or air. 
 
 

 3.2 Electrical:

 

 

 

connection of all electrical signals via one connector 

 

control using display and buttons 

o

 

alphanumeric LED display to show parameters 

o

 

4 buttons for easy parameter setting 

o

 

3 LEDs to display the status: 

 

green - flashes when the unit is in operation 

 

yellow - indicates the presence of material the field of view 

 

red - warning or malfunction of the unit 

 

built-in diagnostics unit: 

o

 

detection of exceeding the internal temperature over 60 ° C 

o

 

detection of a motor speed failure 

o

 

detection of power failure 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SDIS - 1050

Page 1: ...USER MANUAL Universal position sensor and hot metal detector SDIS 1050...

Page 2: ...so that the infrared radiation is reflected to the photocell from each facet of rotating mirror very accurate even in the case when the entire sensing field is covered with hot material Radiation rec...

Page 3: ...ing made of aluminum alloy suport wall with mounting stand adjustable in both directions adapted to the cooling unit with water and blowing air windscreen to prevent pollution connection of water and...

Page 4: ...ndicular to the measured product When selecting the location of the sensor attention to the following must be paid Other source of infrared radiation in addition to the measured material can not inter...

Page 5: ...onnecting the cooling water and air and setting changes the sensor mounting 4 4 1 Cooling The cooling channel housing is positioned allowing the cooling water sensor Conditions for cooling The sensor...

Page 6: ...ron etc The temperature range depends on the infrared radiation of the product Angles standard sensor is supplied with a viewing angle of 50 degrees with a special mask inside the aperture angle can b...

Page 7: ...Operating temperature 10 C to 60 C At an ambient temperature above 40 C it is recommended to cool sensor with industrial water at a temperature up to 25 C pressure of 1 2 bar flow rate of 1 2 l min P...

Page 8: ......

Page 9: ...selected gain Thre 25 selected threshold Mode LS selected operation mode of the sensor LS or HMD Laser 0 press button to light up the targeting laser for 2 minutes Laser 1 Failure message can be flas...

Page 10: ...Set Rel Rel value set is chosen by external relay Man1 measure according ValSet1 Man2 measure according ValSet2 Window Beg 5 beginning of measuring window analog output 4mA position 0 End 95 ending o...

Page 11: ...s setting End 0 90 distance between laser to end of meas window meters Outputs AnOut1 I output signal Analog 1 I intensity P position setting of analog AnOut2 P output signal Analog 2 I intensity P po...

Page 12: ...detection is proportional to material position in the sensor s field of view Additionally sensor can be set to HMD mode hot metal detector sensor only detects if signal from PbS photocell exceeds thr...

Page 13: ...ilters of output signals to improve accuracy or to avoid false detection By adjusting SiUp and SiDo values you can specify how many times signal must be detected befor output detection signal is set o...

Page 14: ...sh pull C gray presence of material detect 24VDC max 50mA H ping neg presence of material detect 0VDC max 50mA M black neg alarm all OK 24VDC max 50mA alarm 0VDC Relay outputs E brown thick w presence...

Reviews: