4. The mounting and wiring 

                              

 4.1. Location

 

  

The distance between the SDIS and the measured product is not critical and depends on the 
scanning angle so as to cover the entire measurement field. Measured product may not fill the 
entire sensor field of view. Just intersects only a portion of 1 cm ² at a distance of 4 m sensor 
The optimal distance between the sensor and the various types of materials are as follows: 
 

 

Material 

Distance between product and sensor 

Wires with a diameter of 5-12 mm 

0,20 – 3 m 

Small bars, 10 × 10 to 40 × 40 

0,20 – 4 m 

Billets and small beams 

0,50 – 6 m 

Blooms 

minimum 2 m 

Thin sheets 

1,00 – 6 m 

Thick plates 

1,00 – 8 m 

Slabs 

minimum 2m 

 
For very hot products it is the best to place the sensor as far as possible to avoid excessive 
destruction due to direct radiation. 
For cold and less-emitting products is the signal-to-noise ratio increased by placing sensors in 
the shortest possible distance. 
The sensing surface should ideally be perpendicular to the measured product. 
When selecting the location of the sensor attention to the following must be paid: 

 

Other source of infrared radiation in addition to the measured material can not intersect 

the  sensor  field  of  view  (door  furnace,  the  reflection  of  the  product  in  the  water  pool,  sun 
reflection from shiny metal in the area, etc.) 

 

Field of view of sensor must not be covered with any other product than the product being 

measured 

 
 

4.2. Mounting

 

 
SDIS has an adjustable mounting foot allows horizontal rotation 
and vertical tilt. Mounting base is fitted with 18 mm hole for 
mounting on the structure. 
The stand is strong enough to ensure a perfect fit sensor. The sensor 
is equipped with connections for enclosure cooling water and 
compressed air for cleaning and protection of optics. 
They can be used in heavy metallurgical environments (high 
temperature, humidity, dust). 
In some cases, however, it is useful to protect the sensor with the heat resistant screen and in 
the case of excessive steam with additional ventilation. To increase the detection accuracy and 
lifetime of the sensor should be mounted on a solid, non-shaking pedestal. 
  
  
 
 

Air 

Water 

Summary of Contents for SDIS - 1050

Page 1: ...USER MANUAL Universal position sensor and hot metal detector SDIS 1050...

Page 2: ...so that the infrared radiation is reflected to the photocell from each facet of rotating mirror very accurate even in the case when the entire sensing field is covered with hot material Radiation rec...

Page 3: ...ing made of aluminum alloy suport wall with mounting stand adjustable in both directions adapted to the cooling unit with water and blowing air windscreen to prevent pollution connection of water and...

Page 4: ...ndicular to the measured product When selecting the location of the sensor attention to the following must be paid Other source of infrared radiation in addition to the measured material can not inter...

Page 5: ...onnecting the cooling water and air and setting changes the sensor mounting 4 4 1 Cooling The cooling channel housing is positioned allowing the cooling water sensor Conditions for cooling The sensor...

Page 6: ...ron etc The temperature range depends on the infrared radiation of the product Angles standard sensor is supplied with a viewing angle of 50 degrees with a special mask inside the aperture angle can b...

Page 7: ...Operating temperature 10 C to 60 C At an ambient temperature above 40 C it is recommended to cool sensor with industrial water at a temperature up to 25 C pressure of 1 2 bar flow rate of 1 2 l min P...

Page 8: ......

Page 9: ...selected gain Thre 25 selected threshold Mode LS selected operation mode of the sensor LS or HMD Laser 0 press button to light up the targeting laser for 2 minutes Laser 1 Failure message can be flas...

Page 10: ...Set Rel Rel value set is chosen by external relay Man1 measure according ValSet1 Man2 measure according ValSet2 Window Beg 5 beginning of measuring window analog output 4mA position 0 End 95 ending o...

Page 11: ...s setting End 0 90 distance between laser to end of meas window meters Outputs AnOut1 I output signal Analog 1 I intensity P position setting of analog AnOut2 P output signal Analog 2 I intensity P po...

Page 12: ...detection is proportional to material position in the sensor s field of view Additionally sensor can be set to HMD mode hot metal detector sensor only detects if signal from PbS photocell exceeds thr...

Page 13: ...ilters of output signals to improve accuracy or to avoid false detection By adjusting SiUp and SiDo values you can specify how many times signal must be detected befor output detection signal is set o...

Page 14: ...sh pull C gray presence of material detect 24VDC max 50mA H ping neg presence of material detect 0VDC max 50mA M black neg alarm all OK 24VDC max 50mA alarm 0VDC Relay outputs E brown thick w presence...

Reviews: