![SSD Parvex DIGIVEX Little Drive Servoamplifier User And Commissioning Manual Download Page 73](http://html1.mh-extra.com/html/ssd-parvex/digivex-little-drive-servoamplifier/digivex-little-drive-servoamplifier_user-and-commissioning-manual_1354499073.webp)
DIGIVEX Little Drive Servoamplifier
71
PVD 3530 GB 01/2005
Diggb43.D/47W
N.B. I+ and I- are to be taken with their sign. In general I- is negative.
In principle:
Gravity =
I
I
2
+
−
+
in Amps (horizontal motion, gravity = 0).
Static friction =
I
I
2
+
-
−
in Amps.
Enter these values into the parameters.
Enter the threshold value (e.g. threshold = max. speed / 1000).
After introducing the values, the result obtained can be checked with the same stimulus.
Check the input set point on one channel and the P, PI, PI
2
output on the other channel. This
should give a result close to:
P, PI, PI
≤
Output
Time
Current
reference
Input
reference
Time
Time
This manual was downloaded on www.sdsdrives.com