![SSD Parvex DIGIVEX Little Drive Servoamplifier User And Commissioning Manual Download Page 17](http://html1.mh-extra.com/html/ssd-parvex/digivex-little-drive-servoamplifier/digivex-little-drive-servoamplifier_user-and-commissioning-manual_1354499017.webp)
DIGIVEX Little Drive Servoamplifier
15
PVD 3530 GB 01/2005
1.3.3.8 Monitoring reasons for stoppage
This monitoring may, through strategic choice, entail either stoppage or reduced performance for
certain faults related to current.
Variables monitored :
Mean drive current.
Output current (short-circuit).
Dissipater temperature.
Motor temperature.
Ambient temperature.
Overspeed.
No resolver.
Maximum and minimum dc bus voltages.
1.3.3.9 General characteristics of the DIGIVEX Little Drive
Power reduction with altitude
Above 1000 m, service power falls by 1% for every 100 m up
to a maximum altitude of 4000 m
Operating temperature
relative humidity
Normal use: 0 - 40°C
Above 40°C, service power falls by 20% for every 10°C up to
a maximum temperature of 60°C.
The variable speed drive stops when the ambient temperature
exceeds 60°C.
85% (without condensation)
Storage temperature
-30°C to +85°C
Chopping frequency
8 kHz
Current bandwidth
600Hz to -3dB
Speed bandwidth
Up to 200Hz
Minimum speed
Minimum speed 0.05 rpm or 1/8000th of maximum speed
Maximum speed
Driven by DIGIVEX : 100 000 rpm
Speed static precision for load
variation from 0 to In and for
rated voltage of DIGIVEX Little
Drive
With analog set point: 1% whatever the speed
Electrical protection
Electrical isolation of power bridge
Mean current protection depending on drive rating
Pulse current protection of drive and motor
rms current protection of motor
Protection against short circuits at bridge output
Mechanical protection
IP20 under IEC 529
Pollution degree
UL : 2
To rise in a surrounding wall
Other monitoring
Motor temperature
Drive temperature
Resolver power supply
Brake supply
This manual was downloaded on www.sdsdrives.com