SD25 Series Screwdrivers
Page 14
T-40409-A
39-30-40409
Mapping Screwdriver Functions
This section describes how VS is used to map screwdriver functions to the buttons and switches on
the screwdriver. You can also use VS to change the default mapping. To do this, refer to the
Visual
Supervisor User’s Guide
(part number 39-30-34823).
Disabling the Push-to-Start Function
Typically, to start a fastening cycle when the push-to-start function on a handheld screwdriver is
disabled:
•
Press the throttle/trigger lever to start the fastening cycle.
•
Release the throttle/trigger lever to stop the fastening cycle.
Throttle/trigger lever
Forward/reverse button
•
Press to start the fastening cycle
•
Release to stop the screwdriver
•
Press and release
2 times
to change the
parameter set
•
Press and release to
change the direction
Multi-purpose (auxiliary) button
•
Disabled