28
Anybus Option Modules
4.8.2 Baud Rate
The Baud Rate is set by parameter
224)FBUS
224)FBUS
BAUD
BAUD
RATE
RATE
.
0
125kbps
1
250 kbps
2
500 kbps
3
800 kbps
4
1 Mbps
4.8.3 Device Address
The Device Address is set by parameter
202)FBUS
202)FBUS
NODE
NODE
ID
ID
.
Note that a power cycle of the drive may be necessary before a change takes effect.
4.8.4 Cyclic Data
The Cyclic Data (Process Data) is transferred using the TPDOs and RPDOs.
GET FROM words 1 to 4 are allocated to TPDO 1
GET FROM words 5 to 8 are allocated to TPDO 2
GET FROM word 9 is allocated to TPDO 3
GOTO words 1 to 4 are allocated to RPDO 1
GOTO words 5 to 8 are allocated to RPDO 2
GOTO word 9 is allocated to RPDO 3
4.8.5 Acyclic Data
Acyclic Data (parameter read/write) is transferred using SDO transfers. The parameters are
directly mapped as vendor-specific objects.
Index
= 2000h + parameter number
Subindex
= 0
Size
= 2 (bytes)
For example:
409)SUMMER
409)SUMMER
1
1
INPUT
INPUT
2
2
is
Index:Subindex 2199h:0
4.8.6 Electronic Data Sheet
CANopen eds files:
SPRINT_PLX.EDS
PLX
M40
SPRINT_JLX.EDS
JLX
M40
SPRINT_PLX_M30.EDS
PLX
M30
SPRINT_JLX_M30.EDS
JLX
M30