Configuring FIELDBUS
3.3.3 213)FBUS BITS OUTPUT
Monitor BIT-PACKED bits from PLC (GOTOs).
PIN Parameter description
Range
213
FIELDBUS BITS OUTPUT
00000000 - 11111111
213)FBUS
213)FBUS
BITS
BITS
OUTPUT
OUTPUT
is the 16-bit WORD being
received from the PLC (PLC OUTPUT) which is being
used to set the configured
BIT-PACKED
BIT-PACKED
GOTO
GOTO
s.
R
ENTRY MENU LEVEL
ENTRY MENU LEVEL
1
1
R
DIAGNOSTICS
DIAGNOSTICS
2
2
R
FIELDBUS 3
FIELDBUS 3
R
213)FBUS BITS OUTPUT
213)FBUS BITS OUTPUT
3.3.4 223)ANYBUS TYPE
Displays the Anybus option fitted.
PIN Parameter description
Range
223
ANYBUS TYPE
See below
Parameter
223)ANYBUS
223)ANYBUS
TYPE
TYPE
diagnostic shows the
specific ANYBUS fieldbus module fitted.
This information may be required to determine which
Electronic Data Sheet file to be used to configure the
PLC.
R
ENTRY MENU LEVEL
ENTRY MENU LEVEL
1
1
R
DIAGNOSTICS
DIAGNOSTICS
2
2
R
FIELDBUS 3
FIELDBUS 3
R
223)ANYBUS TYPE
223)ANYBUS TYPE
Range:
0 NOT FITTED
1 NOT SUPPORTED
2 PROFIBUS DPV1
3 PROFINET
4 ETHERNET/IP
5 MODBUS TCP
6 DEVICENET
7 CANOPEN
8 ETHERCAT
9 PROFIBUS DPV1 (M30)
10 PROFINET (M30)
11 ETHERNET/IP (M30)
12 MODBUS TCP (M30)
13 DEVICENET (M30)
14 CANOPEN (M30)
15 ETHERCAT (M30)
16 PROFINET 1P (M30)
17 ETHERNET/IP 1P (M30)
18 MODBUS TCP 1P (M30)