19
Anybus Option Modules
4.4 EtherNet/IP
4.4.1 Fieldbus Interface
1
Network Status LED
2
Module Status LED
3
Link/Activity LED (port 1)
4
Link/Activity LED (port 2)
4.4.1.1
Network Status LED
NOTE
: A test sequence is performed on this LED during start-up.
LED State
Description
Off
No power or no IP Address
Green
Online, one or more connections established (CIP Class 1 or 3)
Green, flashing
Online, no connections established
Red
Duplicate IP address,
Red, flashing
One or more connections timed out (CIP Class 1 or 3)
4.4.1.2
Module Status LED
NOTE
: A test sequence is performed on this LED during start-up.
LED State
Description
Off
No power
Green
Controlled by a Scanner in Run state
Green, flashing
Not configured, or Scanner in Idle state
Red
Major fault
Red, flashing
Recoverable fault(s)
4.4.1.3
LINK/Activity LED
LED State
Description
Off
No link, no activity
Green
Link (100 Mbit/s) established
Green, flickering
Activity (100 Mbit/s)
Yellow
Link (10 Mbit/s) established
Yellow, flickering
Activity (10 Mbit/s)