28
Specifications
10.2 Rating table
APPLICATION AREA:
Industrial (non-consumer) "Motor speed control utilising DC Motors".
Each drive has the same features and terminals. Select the appropriate model depending on
the motor current and the available supply voltage.
DRIVE TYPE
3600XRi
AC SUPPLY
DUAL
VOLTAGE
NOMINAL
OUTPUT
VOLTAGE
100% Amps
dc output
(Adc)
ISOLATION
MAXIMUM I
2
t
FOR FUSING
4/LN
240/110
180/90
4 A
isolated
510 A
2
seconds
8/LN
240/110
180/90
8 A
isolated
510 A
2
seconds
16/LN
240/110
180/90
16 A
isolated
510 A
2
seconds
16/LL
415/240
320/180
16 A
isolated
510 A
2
seconds
32/LL
415/240
320/180
32 A
isolated
5000 A
2
seconds
36/LL
415/240
320/180
36 A
isolated
5000 A
2
seconds
1. Low volt versions are available, operating on 60/30 Vac supplies giving 48/24 Vdc
output and 48/24 Vac supplies giving 38/18 Vdc output.
2. Top terminals can be added on request.
3. All types are of open-chassis construction with rear heatsink.
4. Nominal output is based on a maximum Form Factor (ratio of RMS ac supply current
to dc output) of 1.5.