7.8 TANK LEVEL (LEVEL SENSOR)
If your configuration includes a pressure pot with a level switch, select the edit button and use the drop down menu to
activate the level sensor signal. Once turned on the 1750+ can now see the low level condition.
Tank level sensor settings
Editing tank level sensor settings
TANK LEVEL SENSOR SETTINGS
•
Input status
—Shows low level regardless if input is turned on.
•
Status
—If input is turned on and level is low this will toggle on.
•
Invert signal
—If you have a normally open level switch (open until liquid level goes low) do not turn this on, if you
are using a normally closed float, toggle this on.
•
Standby on fault
—If you want the spray to stop when level goes low toggle this on.
ATTENTION: When the tank level is low, the 1750+ will show a fault on the screen (tank low), but it will not
stop the nozzle from spraying. Toggle on
“
Go to standby on fault
”
if you want the 1750+ to stop spraying
when the tank level gets low. The level sensor will send the alarm signal based on its current configuration
values.