36
12.1 ELECTRIC NOZZLE CORD SET
If the system is designed to operate Spraying Systems Co.
®
PulsaJet or AA250 electric actuated spray nozzles, the sys-
tem is supplied with a cord to connect the spray nozzle to the Control Panels. All the electric actuated nozzle cord sets
are wired as shown in the diagram.
AA10000 SERIES PULSAJET NOZZLE CABLE
•
Panel connection: Main
•
Part number: LEXXSD3M83F030P
•
Cable: 9.8 ft. [3 m] cord length
•
Connector –
M8 3 pin female
•
Connector –
M12 3 pin male
AA250AUH ELECTRIC NOZZLE CABLE
•
Panel connection: Main
•
Part number: LE00M12MMDIN3MU
•
Cable: 9.8 ft. [3 m] cord length
•
Connector –
Mini DIN
•
Connector –
M12 3 pin male
ELECTRICAL JUNCTION BLOCK
If multiple PulsaJet or AA250 electric spray nozzles are used the system comes complete with a junction block to con-
nect the spray nozzles to the unit. The junction block is available in two versions: four (4) and eight (8) nozzle connec-
tions.
12.2 TRIGGER CABLE
Optional trigger cable offering: Un
-
terminated flying lead cable and connector.
REQUIRED INPUT
•
Part number
-
LE00M12F5M –
M12(f) x bare lead trigger cable
•
NPN –
Switch to 0 VDC to turn on spray trigger.
Requires NPN Sensor or dry contact switch.
•
Connects to the connector labeled
“
Trig.
”
On the bottom of the panel.
ASSEMBLY SPECIFICATIONS:
•
Panel connection: Trig (Software trigger choice
-
DI2)
•
Cable: 16.4 ft. [5 m] cord length
•
Flying Leads
•
Connector end—M12 4 pin female
SECTION 12
TRIGGER DEVICES AND ACCESSORIES
Trigger cable