PARAMETERS—ADVANCED NOZZLE SETTINGS
For custom applications, it is possible to change the properties of the nozzle manually. These settings should only be
modified by instruction from qualified SSCO personnel except for the nozzle cycle count.
WARNING: Incorrect settings can permanently damage the spray nozzle!
Negative Pulse:
Pulse time in milliseconds
•
Used to speed up the closing of the electric spray nozzle, duration is dependent on nozzle model and supply volt-
age.
Gun (Nozzle) Offset:
Offset time in milliseconds
•
The difference in the opening and closing time of the PulsaJet nozzle can be corrected by using the offset value.
The default value is 0ms. For example: If the offset value is set to
-
1ms, the on period will be decreased by 1ms
and the off period will be increased by 1ms.
If a nozzle wear cycle count alarm has been activated, the counter must be reset in this screen after the nozzle has
been replaced.
Editing Advanced Nozzle Settings