16
Application settings
are related to your spray application, and will allow you to customize the spray parameters to
achieve the desired spray coverage and flow rates. These settings will also allow you to configure certain 1750+
accessories, such as the trigger interlock and remote duty cycle if they are included in your specific configuration in
later chapters of the text. This Application Settings section explains the Spray Nozzle Settings, Configuration, Duty
Cycle, Trigger, and Tank Level Sensor Settings.
Note:
Application Settings and Recipe Settings are the same. Use recipe function to configure most settings if the recipe
feature is included in your system configuration.
7.1 SPRAY NOZZLE SETTINGS
The Nozzle Settings page allows for the editing of the Nozzle type and Cycle Speed.
—Nozzle type: nozzle family selection, atomizing air selection, and anticipator/ follower time.
—Cycle speed: allows for the editing of the minimum and maximum cycles per minute.
SELECTING NOZZLE TYPE:
—Nozzle Family: Select the type of nozzle supplied with your system.
—Enable Atomizing Air if your system requires air atomizing.
—Advanced Nozzle Settings allows for editing the PWM settings.
SECTION 7
APPLICATION SETTINGS
Editing Nozzle Type
Nozzle Settings Screen
Application Settings
Color Code: Main
Pin
#
Color
Description
1
Brown
PWM +
2
white
Fault
3
Blue
PWM -
4
Black
N/A