IM-P192-02
MI Issue 2
10
2.5 Technical data
IP rating
IP65 with correct cable glands.
Power supply
Loop powered nominal 24 Vdc
Outputs
4-20 mA (proportional to mass flow)
Pulsed output V
max
28 Vdc,
R
min
10 k
W
, V
on
0.7 V
max
Communication port
EIA 232C 15 m limit - See Section 4.12
RS485 for longer distances
(conversion from RS232)
Performance
System uncertainty to ISO 17025
(95% confidence to 2 STD)
±2% of reading over the range of 10%
to 100% of maximum rated flow
±0.2% FSD from 2% to 10% of
maximum rated flow
Turndown: up to 50:1
2.6 Electrical connections
Electrical connections
M20 x 1.5
2.7 Materials
Unit
Part
Material
TVA
Flowmeter body
Stainless steel S.316 1.4408 CF8M
Internals
431 S29 / S303 / S304 / S316
Spring
Inconel X750 or equivalent
Flowmeter stem
Stainless steel 300 series
Electronics housing Aluminium LM25
Pressure
sensing kit
Cable
Polyvinyl chloride (PVC)
Sensor housing
AISI 304 Stainless steel 1.4301
Sensor
AISI 630 Stainless steel 1.4542
'O' ring
Nitrile Butadiene Rubber (NBR)
Adaptor
AISI 431 Stainless steel 1.4057
High pressure
syphon tube
assembly
Tube
Carbon steel BS 3602: Part.1 1987 CFS 360
(zinc plated / passivated).
Valve
Body
Carbon steel
Seat
PEEK/ Polymain