3.696.5275.210
36
Clean Steam Components - Inspection and replacement
Pressure Safety switch - Replacement
(Fig. 21)
∆
Clean steam and primary supply steam situations can be very dangerous
because of the high temperatures and pressures. To avoid possible injury or death
and follow all accepted and recommended procedures when performing installation,
operation, and maintenance procedures.
∆
The combination of electricity, steam, and water can pose a very dangerous
situation. Turn off / disconnect all electric power before attempting any maintenance
procedures.
The safety pressure switch acts as a fail-safe for Spirax Sarco Compact Steam Generators.
The alarm and shut down for high pressure is set at a value lower than the set of the safety
valve. If the pressure safety switch mounted on the tank is not functioning correctly and
must be replaced, follow the procedures outlined below.
Fig. 20
Summary of Contents for CSM-C
Page 6: ...3 696 5275 210 2...