A–B
B
Appendix
B–1
DTAM Plus Cable Diagrams
Catalog No. 2707-NC1
Use the DH-485 Network Interface Cable to connect the RS-232/RS-485
versions of the DTAM Plus to an SLC DH-485 network.
DTAM Plus RS-485
Comm Port
SLC 500 Programming Port or
Isolated Link Coupler Peripheral Port
8-Pin Male RJ Connector
AMP#5-55179-X
9-Pin Male D Connector
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
Data Out
–
Data Out +
Data In
–
Data In +
Transmit Enable
Ground
Shield
Data (CH A)
Data (CH B)
24 VDC
Gnd RS-485
Transmit Enable TX
–
EN
Shield
Gnd RS-485
24 VDC
Catalog No. 2707-NC2
Use the Upload/Download Cable to connect the RS-232/RS-485 versions of
the DTAM Plus to a personal computer for transferring applications. A 25 to
9 pin adapter is required if your computer has a 25 pin communication port.
DTAM Plus RS-232
Comm Port
Data In
Data Out
Signal Ground
Data In
Data Out
Signal Ground
1
2
3
4
5
1
2
3
4
5
Computer 9 Pin
Serial Port (COM1, COM2)
9-Pin Male D Connector
9-Pin Female D Connector
DTAM Plus Cables
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com