Environmental Specifications
TM 799200, Rev. (4), April 2017
41
Environmental Specifications
4.4
The SafEye system is designed to withstand harsh environmental conditions.
The source and detector units compensate for adverse conditions while
maintaining accuracy.
4.4.1
High Temperature
Designed to meet MIL-STD-810C, Method 501.1 Procedure II
Operating Temperature:
+131ºF/+55ºC
Storage Temperature:
+149ºF/+65ºC
4.4.2
Low Temperature
Designed to meet MIL-STD-810C, Method 502.1, Procedure I
Operating Temperature:
-4ºF/-20ºC
Storage Temperature:
-40ºF/-40 ºC
4.4.3
Humidity
The SafEye system is designed to meet MIL-STD-810C, Method 507.1,
Procedure IV: Relative humidity of up to 95% for the operational
temperature range.
4.4.4
Salt and Fog
The SafEye system is designed to meet MIL-STD-810C, Method 509.1,
Procedure I: Exposure to a 5% salt solution for 48 hours.
4.4.5
Water and Dust
IP67 per EN60529
IP66 per EN60529
Dust:
Completely protected against dust.
Liquids:
Protected against immersion between
15cm and 1m in depth. Protected
against water jets from all directions.
Summary of Contents for SafEye Xenon 700S
Page 2: ...This page intentionally left blank ...
Page 12: ......
Page 16: ......
Page 24: ...Models and Types 24 SafEyeTM Xenon 700S Gas Detector User Guide Figure 1 Wiring Options ...
Page 64: ......
Page 72: ......
Page 76: ......