Electrical Specifications
38
SafEye
TM
Xenon 700S Gas Detector User Guide
Response Time:
3sec to T90
Spectral Response:
3.0–4.0 micron
Sensitivity Range:
0–5 LEL.m
0–2 LEL.m
Field of View:
Line of Sight
Alignment Tolerance:
± 1°
Drift:
Long term ± 5% of full scale
Temperature Range:
-40°F/-40°C to +131°F/+55°C
Immunity to false alarm:
Does not produce a false alarm and is not
influenced by solar radiation, hydrocarbon
flames, or other external IR radiation
sources.
Electrical Specifications
4.2
Operating Voltage:
18–32VDC
4.2.1
Power Consumption
Table 12: Detector and Source Maximum Power Consumption
Without Heated
Optic (Max.)
With Heated
Optic (Max.)
Detector
220mA
300mA
Source
220mA
300mA
4.2.2
Electrical Input Protection
The input circuit is protected against voltage-reversed polarity, voltage
transients, surges, and spikes according to MIL-STD-1275B.
4.2.3
Electrical Interface
There are 3 output-wiring options. These options must be defined at the
factory per the customer order. See
page 67
for wiring/terminal diagrams for each option.
Note
: Option 3 is the default unless otherwise specified at the time of the
order.
Option 1: Power, alarm fault relay, 0–20mA (Figure 9)
Option 2: Power, alarm, fault & accessory relay (Figure 10)
Option 3: Power, alarm relay, RS-485, 0–20mA, RS-485 RTN (Figure 11)
Note
: SIL-2 covers only 0–20mA outputs.
Summary of Contents for SafEye Xenon 700S
Page 2: ...This page intentionally left blank ...
Page 12: ......
Page 16: ......
Page 24: ...Models and Types 24 SafEyeTM Xenon 700S Gas Detector User Guide Figure 1 Wiring Options ...
Page 64: ......
Page 72: ......
Page 76: ......