Flash Source Wiring
TM 799200 Rev. (4), April 2017
53
Flash Source Wiring
5.8
5.8.1
Wiring
To install the wiring:
1
Remove the 4 socket-head-screws (Item 14, Figure 5) that secure
the source back cover (Item 15, Figure 5). The chamber is now
exposed.
2
Remove the protective plug mounted on the source conduit/cable
entry inlet; pull the wires through the source inlet (Item 4, Figure
7). Use a 3/4” – 14NPT or M25x1.5 explosion-proof conduit
connection/cable gland to assemble the cable/explosion-proof
conduit to the source.
3
Connect the wires to the required terminals (Item 2, Figure 7)
(See
page 53).
4
Connect the ground wire to the ground screw outside the source
(Item 3, Figure 7). The source must be well grounded to earth
ground.
5
Check wires for secure mechanical connection and press them
neatly against the terminal to prevent them from interfering while
closing the cover (Item 15, Figure 5).
6
Place and secure the source back cover using 4 socket-head-
screws (Item 14, Figure 5).
5.8.2
Terminal Wiring
The flash source contains a 3-wire strip terminal:
Terminal 1 – positive (+) power supply
Terminal 2 – common return
Terminal 3 – GND (ground)