![SpectraLink IP-DECT SERVER 6500 Installation And Configuration Manual Download Page 54](http://html.mh-extra.com/html/spectralink/ip-dect-server-6500/ip-dect-server-6500_installation-and-configuration-manual_1343882054.webp)
Spectralink IP-DECT Server 6500 Installation and Configuration Guide
14215700 Version 3.0
April, 2014
52
In the following example, base station
No. 10
is down. As a consequence, base station
No. 11
must use the alternative sync way on
No. 21
.
Figure 28
Synchronization Chain with Alternative Sync Ways
Figure 29
Synchronization Chain with Alternative Sync Ways
•
No. 0
is the Sync Master (can be numbered 0-255).
•
No. 10 and No. 20: Primary and alternative sync on No. 0.
•
No. 11
: Primary sync on
No. 10
and alternative sync on
No. 21
.
•
No. 21
: Primary sync on
No. 20
and alternative sync on
No. 11
.
•
No. 0
is the Sync Master (can be numbered 0-255).
•
No. 10, No. 20, No. 30, and No. 40: Primary and alternative sync
on No. 0.
•
No. 11
: Primary sync on
No. 10
and alternative sync on
No. 21
.
•
No. 21
: Primary sync on
No. 20
and alternative sync on
No. 11
.
•
No. 31
: Primary sync on
No. 30
and alternative sync on
No. 41
.
•
No. 41
: Primary sync on
No. 40
and alternative sync on
No. 31
.