Spectra Precision Focus 6 5" Total Station User Guide
99
Applications
4
Once the plane is defined, the calculated a and b
values are updated as you move the telescope. No
distance measurement is required.
Using
[DSP]
to switch between display screens
Press
[DSP]
to switch between the plane display screens. The following screens are
available:
Every time you press
[DSP]
, the next screen appears. If you press
[DSP]
in the last screen
(PLN3), the PLN1 screen appears.
To record the point, press
[ENT]
on any screen (S-PLN1/3
to S-PLN3/3).
Enter PT and CD. Then press
[ENT]
.
Sample records
CO,3ptPlane P1:1062 P2:2902 P3:1547
CO,a=31.497 b=14.239
SS,30123-A49,1.6110,0.0000,234.3210,86.0955,16:07:18,
Recording Measurement Data
Recording data from any observation screen
To record points on observation screens, press
[ENT]
.
PT defaults to the last recorded PT + 1.
You can enter the PT name from the point list or the
point stack. For more information, see
.
You can also use the code list or the code stack. For more information, see
code from the code list, page 62
, and
Entering a code from the code stack, page 62
.
a
Distance between P1 and the point that is
perpendicular to the target point along the
P1-P2 line
b
Length of the perpendicular line from the
target point to the P1-P2 line
PLN1
PLN2
PLN3
a
b
X
Y
Z
HA
VA
Summary of Contents for Focus 6
Page 1: ...Spectra preciSion 6 5 TOTAL STATION...
Page 2: ...Blank page Inside cover...
Page 3: ...Version 1 00 Revision A October 2009 User Guide Spectra Precision Focus 6 5 Total Station...
Page 6: ...4 Spectra Precision Focus 6 5 Total Station User Guide...
Page 12: ...Safety 10 Spectra Precision Focus 6 5 Total Station User Guide...
Page 24: ...1 Introduction 22 Spectra Precision Focus 6 5 Total Station User Guide...
Page 112: ...4 Applications 110 Spectra Precision Focus 6 5 Total Station User Guide...
Page 170: ...7 Specifications 168 Spectra Precision Focus 6 5 Total Station User Guide...
Page 174: ...8 System Diagrams 172 Spectra Precision Focus 6 5 Total Station User Guide...
Page 190: ...9 Communications 188 Spectra Precision Focus 6 5 Total Station User Guide...