Spectra Precision Focus 6 5" Total Station User Guide
127
Menu Key
5
Advanced feature: Entering angle and distance offsets
To display the offset input screen, press the
O/S
softkey.
In the Ang field, enter a positive value to rotate the line
clockwise. Enter a negative value to rotate the line
counterclockwise.
In the O/S field, enter a positive value to specify an offset to the right. Enter a negative
value to specify an offset to the left.