5
Menu Key
134
Spectra Precision Focus 6 5" Total Station User Guide
Data
Use the Data menu to view or edit records. To display
the Data menu, press
[4]
on the MENU screen.
Viewing records
B
Tip –
You can view data at any time, even in an observation screen or while entering
points.
Viewing raw data
To show the raw data records in a list, press
[1]
on the
Data menu screen.
When you first view the raw data, the last four raw
records in the current job are displayed. Use
[^]
or
[v]
to
scroll through the records.
To see detailed information for the selected records,
press
[ENT]
.
To return to the record list, press
[ESC]
.
SS, CP, F1 records
Raw SS, CP and F1 records contain PT, HT, CD, HA, VA, and SD fields.
SS records are sideshots (topo shots). All shots from the Basic Measurement Screen
(BMS) are stored as SS records.
CP records are shots taken in the Angle or Repeat menus, or in the BMS. For more
information, see
Recording a foresight point after repeat angle measurement, page 70
,
and
Recording data from any observation screen, page 99
When the Store DB setting is set to RAW+XYZ, press
[DSP]
to switch between the first
screen (showing HA, VA, SD, PT, and HT) and the second screen (showing X, Y, Z, PT,
and CD).
Coordinates are not available in F1 records.
When you take more than one measurement to the same point and choose to
overwrite the XYZ data, the old raw record becomes raw data only. As a result, only one
SS(RAW) record keeps its corresponding SS(XYZ) record. Other SS(RAW) records to
the same point no longer have coordinates available.
Summary of Contents for Focus 6
Page 1: ...Spectra preciSion 6 5 TOTAL STATION...
Page 2: ...Blank page Inside cover...
Page 3: ...Version 1 00 Revision A October 2009 User Guide Spectra Precision Focus 6 5 Total Station...
Page 6: ...4 Spectra Precision Focus 6 5 Total Station User Guide...
Page 12: ...Safety 10 Spectra Precision Focus 6 5 Total Station User Guide...
Page 24: ...1 Introduction 22 Spectra Precision Focus 6 5 Total Station User Guide...
Page 112: ...4 Applications 110 Spectra Precision Focus 6 5 Total Station User Guide...
Page 170: ...7 Specifications 168 Spectra Precision Focus 6 5 Total Station User Guide...
Page 174: ...8 System Diagrams 172 Spectra Precision Focus 6 5 Total Station User Guide...
Page 190: ...9 Communications 188 Spectra Precision Focus 6 5 Total Station User Guide...