background image

4

WARNING: 

Before Installing this product, read and follow all warning notices and instructions which are included. 

Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call 
(800) 223-8538 or visit www.usa.speck-pumps.com for additional copies of these instructions.

 

Important Safety Instructions

Important Notice:

This manual contains important information about the installation, operation and safe use of this product. This 
information should be given to the owner and/or operator of this equipment. 

WARNING: 

This product must be installed and serviced by a qualified pool professional, and must conform to all 

national, state, and local codes. 

WARNING: 

Before Installing this product, read and follow all warning notices and instructions which are included. 

Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call 
1-800-223-8538 or visit www.usa.speck-pumps.com for additional copies of these instructions.

When installing and using this electrical equipment, basic safety precautions should always be followed, 

including the following:

READ AND FOLLOW ALL INSTRUCTIONS

WARNING:

 To reduce the risk of injury, do not permit children to use this product unless they are closely 

supervised at all times.

WARNING:

 Risk of Electrical Shock. Connect only to a grounding type receptacle protected by a ground-fault 

circuit-interrupter (GFCI). Contact a qualified electrician if you cannot verify that the receptacle is protected by 
a GFCI.

The unit must be connected only to a supply circuit that is protected by a ground-fault circuit-interrupter (GFCI). 
Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push 
the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI 
fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the pump without the test 
button being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this 
pump. Disconnect the pump and have the problem corrected by a qualified service representative before using.

CAUTION:

 This pump is for use with permanently installed pools and may also be used with hot tubs and spas if 

so marked. Do not use with storable pools. A permanently installed pool is constructed in or on the ground or in 
a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it may 
be readily disassembled for storage and reassembled to its original integrity.

TO REDUCE THE RISK OF ELECTRICAL SHOCK, 

connect ground wires to grounding screw located in the motor. 

Use no smaller than a #12 AWG (3.3mm

2

) wire.

TO REDUCE THE RISK OF ELECTRICAL SHOCK, 

a bonding connector is provided for bonding to metal water 

pipes, metal rails, or other metal within 5 feet of the swimming pool. All local points should be bonded with a #8 
AWG (8.4mm

2

) wire.

SAVE THESE INSTRUCTIONS.

Summary of Contents for 1.1 THP Dual Voltage Series

Page 1: ...Installation Operation and Service Manual 1 1 THP Dual Voltage Series Variable Speed Pool Pump Motor Version 2 0 02 2019...

Page 2: ...Bayberry Road Jacksonville FL 32256 USA Hours Monday Friday 8 00 am to 5 00 pm EST Toll Free 800 223 8538 Phone 904 739 2626 Fax 904 737 5261 Website www usa speck pumps com Email technical usa speck...

Page 3: ...ks 9 Pressure Testing 9 4 Operation 10 Start Up guide 10 Enter Programming Mode 11 Schedule SCHE Menu 12 Override OVRD Menu 13 Priming PR Menu 13 Normal Operation 14 User Interface Lockout 15 5 Servic...

Page 4: ...ult circuit interrupter GFCI Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI The unit must be connected only to a supply circuit that is protected by a...

Page 5: ...rapment If not a single unblockable outlet in the event of one suction outlet being completely blocked the remaining suction outlets serving the system shall have a flow rating capable of the full flo...

Page 6: ...level for your application These variable speed pumps are designed to meet the needs of today s more environmentally friendly consumer The pump parts are made of 100 recyclable environment friendly p...

Page 7: ...tenance 4 Install the pump in a well ventilated location protected from direct sunlight and excessive moisture rain sprinklers etc 5 Protect the pump against flooding and excess moisture and prevent f...

Page 8: ...nded that thread seal tape be used Hard plumbed pipes must have proper solvent weld connections Flexible hose connections must be tightened properly If the suction line is not sealed correctly the pum...

Page 9: ...er performance and long motor life Incorrect voltage will cause the error light to turn on and cause damage to the motor if not turned off immediately It is the responsibility of the electrical instal...

Page 10: ...starting this procedure 1 Release all pressure from the system and open the filter pressure release valve 2 Depending on the location of the pump do one of the following 4 Operation Start Up Guide If...

Page 11: ...followed check for a suction leak If there is a leak repeat Steps 2 through 6 NOTE It is normal for a few drops of water to escape from the mechanical seal from time to time This is especially true d...

Page 12: ...isplay Use the and buttons to select the desired power level Watts Press the button to save the power level and move on to the duration setting See Figure 6 1 ERROR 3 OK 2 ERROR POWER SET OK 0 3 2 1 2...

Page 13: ...eature First press the button and then the button simultaneously when the pump is running The pump will ramp up to full speed 1000 Watts for the programmed override duration At the end of the programm...

Page 14: ...ctory Default Schedule is S1 200 Watts 12 Hours S2 0 Watts 0 Hours S3 0 Watts 0 Hours Under the default schedule the pump will run at 200W for 12 hours and then remain off for 12 hours every day NOTE...

Page 15: ...ll with water up to the suction pipe Clean the clear lid o ring and sealing surface of the pump of any debris 7 Replace lid with lid ring Hand tighten the lid to make an air tight seal DO NOT use any...

Page 16: ...The pump must be protected when freezing temperatures are expected Allowing the pump to freeze will cause severe damage and void the warranty There are two options when winterizing the pump Option 1 1...

Page 17: ...tep does not clear the error code contact your pool professional for service 6 Troubleshooting Table 2 0 Figure 5 Error Code Error Description 01 DC link over voltage 02 DC link under voltage 03 DC li...

Page 18: ...the pump starts while your hand is inside the pump 1 Turn OFF the pump Switch off the circuit breaker to the pump motor If you are not replacing the motor do not disconnect the electrical wiring Probl...

Page 19: ...ing water with a small amount of dish soap brush the impeller shaft for ease of assembly 10 With the carbon side up push the mechanical onto the impeller shaft and wipe carbon surface with a clean clo...

Page 20: ...using to the pump casing strainer tank 3 Slide the motor and flange seal housing away from the casing stainer tank 4 Remove the diffuser by gently pulling the diffuser horizontally until the pins are...

Page 21: ...RPM 100 Watts 1300 1700 RPM 0 U S Gallons Per Minute 10 30 50 20 40 60 80 100 90 70 10 20 30 40 50 60 70 Total Head in Feet B A C Model E71 II VHV 1000 Watts 2650 3250 RPM 450 Watts 2000 2450 RPM 0 U...

Page 22: ...1 LID CLEAR LID CLEAR with LED LIGHT LOCK RING WITH HANDLES LID O RING LID 137 x 5mm BASKET ONE PIECE CASING DRAIN CAP 3 8 WITH GASKET CASING LEGO SPACER SCREW CASING HEX SLOT M7 x 48mm SS O RING DIFF...

Page 23: ...NG LID LID CLEAR O RING LID 105 x 5mm COMPLETE UNION PACKAGE SUCTION DISCHARGE SLIP HOSE COMPLETE UNION PACKAGE SUCTION DISCHARGE HOSE COMPLETE UNION PACKAGE SUCTION DISCHARGE SLIP COMPLETE UNION PACK...

Page 24: ...O RING LID 137 x 5mm BASKET ONE PIECE O RING CASING 144 x 4mm IMPELLER II 1 1THP 106 9mm W INSERT SCREW CASING HEX WASHER SLOT M7 x 48mm CASING DUAL DISCHARGE MECHANICAL SEAL 5 8 CARBON CERAMIC STRAIN...

Page 25: ...le for an extended warranty Only products purchased through a pool service company a pool builder or a pool store AND installed by a pool professional along with a licensed electrician are eligible fo...

Page 26: ...M THE USE OF OR INABILITY TO USE THE PUMP AND MOTOR OR THE PERFORMANCE OR NONPERFORMANCE OF ANY OBLIGATION UNDER THIS LIMITED WARRANTY THIS PARAGRAPH THE WARRANTY DISCLAIMERS IN PARAGRAPH 4 ABOVE AND...

Page 27: ...27...

Page 28: ...2999999406 Rev 0717...

Reviews: