background image

5

F

General Safety Instructions

The following guidelines provide information to minimize the risk of injury to users of 

pools, spas, and hot tubs. 

WARNING: TO REDUCE THE RISK OF ENTRAPMENT HAZARD

Pool and spa pumps produce high levels of suction, which can pose extreme danger if a person comes in close 
proximity to an open pool or spa drain or if a drain cover is loose, cracked, broken or missing. Pool and spa pumps 
move large volumes of water, which can pose extreme danger if a person’s hair comes in close proximity to a 
drain that is not the proper size for the pump or pumps.

If not an approved single, unblockable outlet, a minimum of two functioning suction outlets per pump must be 
installed. Suction outlets in the same plane (i.e. floor or wall) must be installed a minimum of three (3) feet (1 
meter) apart, as measured from center point to center point. Dual suction fittings shall not be located on seating 
areas or on the backrest for such seating areas. If any suction outlets are located closer they shall be located on 
two different planes (i.e. one on the bottom and one on the vertical wall, or one each on two separate vertical 
walls). 

WARNING: Failure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper and other 
material can result in an increased potential for suction entrapment.

If not a single, unblockable outlet, in the event of one suction outlet being completely blocked, the remaining 
suction outlets serving the system shall have a flow rating capable of the full flow of the pump(s) or the specific 
suction system. If in doubt about the rating and/or head loss curve of your system, consult a qualified pool or 
spa professional and/or your respective equipment manufacturer(s). Also, double check with your local building/
health authorities regarding single vs. multiple drain installations, etc.

Regularly inspect all drain covers for cracks, damage and advanced weathering. If a drain cover becomes loose, 
cracked, damaged, broken or is missing, close the pool or spa immediately, post a notice and keep the pool or spa 
closed until an appropriate VGB 2008 certified drain cover is properly installed.

WATER VELOCITY AND FLOW RATES

The maximum water velocity through drain covers is limited by some local regulations, for example some state 
health departments limit the velocity through public pool drain covers to 1.5 feet per second. This velocity limit 
is lower than the flow rating provided by the ANSI/APSP 16 certification; therefore local limit applies and must 
be followed. Never exceed the flow rating listed on the cover even if local code does not provide a velocity limit.

For additional information on proper installation refer to The Association of Pool & Spa Professionals ANSI/APSP-
7 Standard and the US Consumer Product Safety Commission Guidelines for Entrapment Hazard.

Summary of Contents for 1.1 THP Dual Voltage Series

Page 1: ...Installation Operation and Service Manual 1 1 THP Dual Voltage Series Variable Speed Pool Pump Motor Version 2 0 02 2019...

Page 2: ...Bayberry Road Jacksonville FL 32256 USA Hours Monday Friday 8 00 am to 5 00 pm EST Toll Free 800 223 8538 Phone 904 739 2626 Fax 904 737 5261 Website www usa speck pumps com Email technical usa speck...

Page 3: ...ks 9 Pressure Testing 9 4 Operation 10 Start Up guide 10 Enter Programming Mode 11 Schedule SCHE Menu 12 Override OVRD Menu 13 Priming PR Menu 13 Normal Operation 14 User Interface Lockout 15 5 Servic...

Page 4: ...ult circuit interrupter GFCI Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI The unit must be connected only to a supply circuit that is protected by a...

Page 5: ...rapment If not a single unblockable outlet in the event of one suction outlet being completely blocked the remaining suction outlets serving the system shall have a flow rating capable of the full flo...

Page 6: ...level for your application These variable speed pumps are designed to meet the needs of today s more environmentally friendly consumer The pump parts are made of 100 recyclable environment friendly p...

Page 7: ...tenance 4 Install the pump in a well ventilated location protected from direct sunlight and excessive moisture rain sprinklers etc 5 Protect the pump against flooding and excess moisture and prevent f...

Page 8: ...nded that thread seal tape be used Hard plumbed pipes must have proper solvent weld connections Flexible hose connections must be tightened properly If the suction line is not sealed correctly the pum...

Page 9: ...er performance and long motor life Incorrect voltage will cause the error light to turn on and cause damage to the motor if not turned off immediately It is the responsibility of the electrical instal...

Page 10: ...starting this procedure 1 Release all pressure from the system and open the filter pressure release valve 2 Depending on the location of the pump do one of the following 4 Operation Start Up Guide If...

Page 11: ...followed check for a suction leak If there is a leak repeat Steps 2 through 6 NOTE It is normal for a few drops of water to escape from the mechanical seal from time to time This is especially true d...

Page 12: ...isplay Use the and buttons to select the desired power level Watts Press the button to save the power level and move on to the duration setting See Figure 6 1 ERROR 3 OK 2 ERROR POWER SET OK 0 3 2 1 2...

Page 13: ...eature First press the button and then the button simultaneously when the pump is running The pump will ramp up to full speed 1000 Watts for the programmed override duration At the end of the programm...

Page 14: ...ctory Default Schedule is S1 200 Watts 12 Hours S2 0 Watts 0 Hours S3 0 Watts 0 Hours Under the default schedule the pump will run at 200W for 12 hours and then remain off for 12 hours every day NOTE...

Page 15: ...ll with water up to the suction pipe Clean the clear lid o ring and sealing surface of the pump of any debris 7 Replace lid with lid ring Hand tighten the lid to make an air tight seal DO NOT use any...

Page 16: ...The pump must be protected when freezing temperatures are expected Allowing the pump to freeze will cause severe damage and void the warranty There are two options when winterizing the pump Option 1 1...

Page 17: ...tep does not clear the error code contact your pool professional for service 6 Troubleshooting Table 2 0 Figure 5 Error Code Error Description 01 DC link over voltage 02 DC link under voltage 03 DC li...

Page 18: ...the pump starts while your hand is inside the pump 1 Turn OFF the pump Switch off the circuit breaker to the pump motor If you are not replacing the motor do not disconnect the electrical wiring Probl...

Page 19: ...ing water with a small amount of dish soap brush the impeller shaft for ease of assembly 10 With the carbon side up push the mechanical onto the impeller shaft and wipe carbon surface with a clean clo...

Page 20: ...using to the pump casing strainer tank 3 Slide the motor and flange seal housing away from the casing stainer tank 4 Remove the diffuser by gently pulling the diffuser horizontally until the pins are...

Page 21: ...RPM 100 Watts 1300 1700 RPM 0 U S Gallons Per Minute 10 30 50 20 40 60 80 100 90 70 10 20 30 40 50 60 70 Total Head in Feet B A C Model E71 II VHV 1000 Watts 2650 3250 RPM 450 Watts 2000 2450 RPM 0 U...

Page 22: ...1 LID CLEAR LID CLEAR with LED LIGHT LOCK RING WITH HANDLES LID O RING LID 137 x 5mm BASKET ONE PIECE CASING DRAIN CAP 3 8 WITH GASKET CASING LEGO SPACER SCREW CASING HEX SLOT M7 x 48mm SS O RING DIFF...

Page 23: ...NG LID LID CLEAR O RING LID 105 x 5mm COMPLETE UNION PACKAGE SUCTION DISCHARGE SLIP HOSE COMPLETE UNION PACKAGE SUCTION DISCHARGE HOSE COMPLETE UNION PACKAGE SUCTION DISCHARGE SLIP COMPLETE UNION PACK...

Page 24: ...O RING LID 137 x 5mm BASKET ONE PIECE O RING CASING 144 x 4mm IMPELLER II 1 1THP 106 9mm W INSERT SCREW CASING HEX WASHER SLOT M7 x 48mm CASING DUAL DISCHARGE MECHANICAL SEAL 5 8 CARBON CERAMIC STRAIN...

Page 25: ...le for an extended warranty Only products purchased through a pool service company a pool builder or a pool store AND installed by a pool professional along with a licensed electrician are eligible fo...

Page 26: ...M THE USE OF OR INABILITY TO USE THE PUMP AND MOTOR OR THE PERFORMANCE OR NONPERFORMANCE OF ANY OBLIGATION UNDER THIS LIMITED WARRANTY THIS PARAGRAPH THE WARRANTY DISCLAIMERS IN PARAGRAPH 4 ABOVE AND...

Page 27: ...27...

Page 28: ...2999999406 Rev 0717...

Reviews: