11
Start Up Guide - continued
Prime Sequence:
If full prime has not been achieved after prime cycle (max. 10 minutes), press the “0” button to stop the
pump. Refill the pump with water and restart. Allow the pump to run for up to 10 minutes to allow air trapped in the suction
line to be purged.
8. The pump has three (3) adjustable power level settings (S1, S2, S3) that run on a 24-hour cycle, starting with S1. Each
setting can be adjust for power level (0-1000 Watts) and duration (0-24 hours).
NOTE: The total duration for S1 + S2+ S3
must be equal to or less than 24 hours.
Default Factory Schedule:
S1: 200W; 12 hours
S2: 0W; 0 hours
S3: 0W; 0 hours
9. If the power is turned off or the pump is stopped using the “0” button, it will repeat the programmed priming cycle and start
from the beginning of the 24-hour cycle (S1) upon restart.
10. If the pump does not prime and all the instructions to this point have been followed, check for a suction leak. If there is a
leak repeat Steps 2 through 6.
NOTE: It is normal for a few drops of water to escape from the mechanical seal from time to
time. This is especially true during the break-in period.
(Refer to section 5.2 - Mechanical Seal on page 16).
11.
For technical support, call 800-223-8538. If calling from outside the U.S. dial +1 904-739-2626.
Enter Programming Mode
1. To enter programming mode, the pump must be in the stopped position. If the pump is running, press the button. OFF
will be shown on the LED display and the green Power LED will flash. See Figure 3.
ERROR
POWER
SET
OK
0
3
2
1
o F F
Figure 3 - OFF Shown On Display
0
2. Press and hold the button for at least three (3) seconds. SCHE will begin flashing on the LED display. See Figure 4.
SET
ERROR
POWER
SET
OK
0
3
2
1
S C H E
ERROR
POWER
SET
OK
0
3
2
1
o U A O
ERROR
POWER
SET
OK
0
3
2
1
P A
Figure 4 - SCHE Shown on Display
3. Use the and buttons to toggle between SCHE (schedule menu), OVRD (override menu), and PR (prime menu). Once
you have selected the menu you wish to enter, press the button.
1
ERROR
3
OK
2
Summary of Contents for 1.1 THP Dual Voltage Series
Page 27: ...27...
Page 28: ...2999999406 Rev 0717...