background image

6

Figure 1

The ES90-II VSP, E71-II VHV, and A91-II VSP family of variable speed swimming pool pumps are both environmentally friendly 
and cost efficient. These pumps have three (3) adjustable power levels which provide the pool owner a simple three button 
control, greatly reducing the operating cost at a reasonable investment. The high performance, medium head pumps use a 
state of the art axial flux permanent magnet brushless-DC motor controlled by advance logic electronics - providing cooler 
and quieter operation at a fraction of the cost of a standard PSC motor. 

The motor runs on a 24-hour schedule, and operates by keeping the power used by the pump at a constant power level 
selected by the user. This is especially useful at lower speeds because as the filter gets dirty and pressure increases, the 
pump will automatically pick up a little speed to keep the programmed power level the same. This allows for longer periods 
of time before the filter needs to be cleaned, and the user knows exactly how much power the pump is using. In addition, the 
motor automatically detects either 115V or 230V power without the need for rewiring or a voltage switch. 

Ideally suited for pools up to 36,000 gallons (24 hour operation), the pumps operate at maximum system flow of 85- 100 
gallons per minute (GPM) at 1000 watts (2850-3500 RPM). The maximum flow rate and RPM are dependant on the pump 
model and installation. The pumps can operate from 10 watts (400-600 RPM) to 1000 watts (2850-3500 RPM) in increments 
of 10 watts. This allows you to select the most appropriate power level for your application. These variable speed pumps 
are designed to meet the needs of today’s more environmentally friendly consumer. The pump parts are made of 100% 
recyclable “environment friendly“ plastic. 

The user interface provides manual power level controls for the pump. There are three fixed power level buttons that can be 
selected 1, 2, and 3.

 (See Figure 1)

 

General Description

Controls and LEDs

Description

1) Power Level Display Displays the current motor power level, or error code.

2)         Button

Used to enter programming mode (press and hold for 
at least 3 seconds).

3)         Button

Used to select fixed power level 1 or to decrease 
power level when in programming mode.

4)         Button

Used to start the pump from the OFF position or 
to confirm/save parameters when in programming 
mode.

5)         Button

Used to select fixed power level 3 or to increase 
speed when in programming mode

6)         Button

Used to stop the motor.

7) Power LED

The green LED indicates the unit has power.

8) Error LED

The red LED indicates there is a fault.

ERROR

POWER

SET

OK

0

3

2

1

(1)

(2)

(3)

(4)

(5)

(6)
(7)

(8)

General Safety Instructions - continued

OK

2

1

ERROR

3

SET

0

Pool pump must be installed by a licensed or certified electrician or a qualified 
pool serviceman in accordance with the National Electrical Code and all applicable 
local codes and ordinances. Improper installation will create an electric hazard 
which could result in death or serious injury to pool users, installers, or others 
due to electrical shock, and may also cause damage to property.

Always disconnect power to the pool pump at the circuit breaker before 

servicing the pump. Failure to do so could result in death or serious injury to 
serviceman, pool users, or others due to electric shock.

WARNING - Risk of Electrical Shock or Electrocution

Summary of Contents for 1.1 THP Dual Voltage Series

Page 1: ...Installation Operation and Service Manual 1 1 THP Dual Voltage Series Variable Speed Pool Pump Motor Version 2 0 02 2019...

Page 2: ...Bayberry Road Jacksonville FL 32256 USA Hours Monday Friday 8 00 am to 5 00 pm EST Toll Free 800 223 8538 Phone 904 739 2626 Fax 904 737 5261 Website www usa speck pumps com Email technical usa speck...

Page 3: ...ks 9 Pressure Testing 9 4 Operation 10 Start Up guide 10 Enter Programming Mode 11 Schedule SCHE Menu 12 Override OVRD Menu 13 Priming PR Menu 13 Normal Operation 14 User Interface Lockout 15 5 Servic...

Page 4: ...ult circuit interrupter GFCI Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI The unit must be connected only to a supply circuit that is protected by a...

Page 5: ...rapment If not a single unblockable outlet in the event of one suction outlet being completely blocked the remaining suction outlets serving the system shall have a flow rating capable of the full flo...

Page 6: ...level for your application These variable speed pumps are designed to meet the needs of today s more environmentally friendly consumer The pump parts are made of 100 recyclable environment friendly p...

Page 7: ...tenance 4 Install the pump in a well ventilated location protected from direct sunlight and excessive moisture rain sprinklers etc 5 Protect the pump against flooding and excess moisture and prevent f...

Page 8: ...nded that thread seal tape be used Hard plumbed pipes must have proper solvent weld connections Flexible hose connections must be tightened properly If the suction line is not sealed correctly the pum...

Page 9: ...er performance and long motor life Incorrect voltage will cause the error light to turn on and cause damage to the motor if not turned off immediately It is the responsibility of the electrical instal...

Page 10: ...starting this procedure 1 Release all pressure from the system and open the filter pressure release valve 2 Depending on the location of the pump do one of the following 4 Operation Start Up Guide If...

Page 11: ...followed check for a suction leak If there is a leak repeat Steps 2 through 6 NOTE It is normal for a few drops of water to escape from the mechanical seal from time to time This is especially true d...

Page 12: ...isplay Use the and buttons to select the desired power level Watts Press the button to save the power level and move on to the duration setting See Figure 6 1 ERROR 3 OK 2 ERROR POWER SET OK 0 3 2 1 2...

Page 13: ...eature First press the button and then the button simultaneously when the pump is running The pump will ramp up to full speed 1000 Watts for the programmed override duration At the end of the programm...

Page 14: ...ctory Default Schedule is S1 200 Watts 12 Hours S2 0 Watts 0 Hours S3 0 Watts 0 Hours Under the default schedule the pump will run at 200W for 12 hours and then remain off for 12 hours every day NOTE...

Page 15: ...ll with water up to the suction pipe Clean the clear lid o ring and sealing surface of the pump of any debris 7 Replace lid with lid ring Hand tighten the lid to make an air tight seal DO NOT use any...

Page 16: ...The pump must be protected when freezing temperatures are expected Allowing the pump to freeze will cause severe damage and void the warranty There are two options when winterizing the pump Option 1 1...

Page 17: ...tep does not clear the error code contact your pool professional for service 6 Troubleshooting Table 2 0 Figure 5 Error Code Error Description 01 DC link over voltage 02 DC link under voltage 03 DC li...

Page 18: ...the pump starts while your hand is inside the pump 1 Turn OFF the pump Switch off the circuit breaker to the pump motor If you are not replacing the motor do not disconnect the electrical wiring Probl...

Page 19: ...ing water with a small amount of dish soap brush the impeller shaft for ease of assembly 10 With the carbon side up push the mechanical onto the impeller shaft and wipe carbon surface with a clean clo...

Page 20: ...using to the pump casing strainer tank 3 Slide the motor and flange seal housing away from the casing stainer tank 4 Remove the diffuser by gently pulling the diffuser horizontally until the pins are...

Page 21: ...RPM 100 Watts 1300 1700 RPM 0 U S Gallons Per Minute 10 30 50 20 40 60 80 100 90 70 10 20 30 40 50 60 70 Total Head in Feet B A C Model E71 II VHV 1000 Watts 2650 3250 RPM 450 Watts 2000 2450 RPM 0 U...

Page 22: ...1 LID CLEAR LID CLEAR with LED LIGHT LOCK RING WITH HANDLES LID O RING LID 137 x 5mm BASKET ONE PIECE CASING DRAIN CAP 3 8 WITH GASKET CASING LEGO SPACER SCREW CASING HEX SLOT M7 x 48mm SS O RING DIFF...

Page 23: ...NG LID LID CLEAR O RING LID 105 x 5mm COMPLETE UNION PACKAGE SUCTION DISCHARGE SLIP HOSE COMPLETE UNION PACKAGE SUCTION DISCHARGE HOSE COMPLETE UNION PACKAGE SUCTION DISCHARGE SLIP COMPLETE UNION PACK...

Page 24: ...O RING LID 137 x 5mm BASKET ONE PIECE O RING CASING 144 x 4mm IMPELLER II 1 1THP 106 9mm W INSERT SCREW CASING HEX WASHER SLOT M7 x 48mm CASING DUAL DISCHARGE MECHANICAL SEAL 5 8 CARBON CERAMIC STRAIN...

Page 25: ...le for an extended warranty Only products purchased through a pool service company a pool builder or a pool store AND installed by a pool professional along with a licensed electrician are eligible fo...

Page 26: ...M THE USE OF OR INABILITY TO USE THE PUMP AND MOTOR OR THE PERFORMANCE OR NONPERFORMANCE OF ANY OBLIGATION UNDER THIS LIMITED WARRANTY THIS PARAGRAPH THE WARRANTY DISCLAIMERS IN PARAGRAPH 4 ABOVE AND...

Page 27: ...27...

Page 28: ...2999999406 Rev 0717...

Reviews: