background image

9

Table 1.0

4. Remove the four screws holding the top control enclosure onto 
the motor. Carefully lift the top panel and turn it over to expose the 
inside terminal box. 

(See Figure 2)

5. The terminal box is supplied with a 1/2” -14 NPT threaded hole. 
Use only liquid tight fittings in order to protect the electronics and 
the motor.  

CAUTION: Failure to use liquid tight fittings will void the 

warranty.

 

6. Connect L1, L2/N, and Ground to the terminal block as shown in 
Figure 2.

7. Carefully fold all wires inside the terminal box and place the top 
control panel back on top of the terminal box.

8. Tighten the four screws into the terminal box while applying light 
pressure to the top control enclosure. 

DO NOT OVER TIGHTEN

.

Electrical Installation - continued

3. Insulate all connections carefully to prevent grounding or short-circuits. Sharp edges on terminals require extra protection. 
To prevent the wire nuts from loosening, tape them using suitable, listed (UL, ETL, CSA) electrical insulating tape. For safety, 
and to prevent entry of contaminants, reinstall all conduit and terminal box covers. Do not force connections into the conduit 
box.

Figure 2

L1

L2/N

Ground

Internal Motor Ground 

(Connected at Factory)

The correct voltage, as specified on the pump data plate, is necessary for proper performance and long motor life. Incorrect 
voltage will cause the error light to turn on and cause damage to the motor if not turned off immediately.

It is the responsibility of the electrical installer to provide data plate operating voltage to the pump by ensuring proper circuit 
sizes and wire sizes for this specific application.

CAUTION: Failure to provide data plate voltage during operation will cause the motor to overheat and void the warranty.

Voltage Checks

Pressure Test

WARNING:

 

When pressure testing a system with water, air is often trapped in the system during the filling process. This air 

will compress when the system is pressurized. Should the system fail, this trapped air can propel debris at a high speed and 
cause injury. Every effort to remove trapped air must be taken, including opening the bleed valve on the filter and loosening 
the pump basket lid while filling the pump. 

WARNING:

 

Trapped air in the system can cause the filter lid to be blown off, which can result in death, serious injury, or 

property damage. Be sure all air is properly purged out of the system before operating. DO NOT USE COMPRESSED AIR TO 

PRESSURE TEST OR CHECK FOR LEAKS.

WARNING: When pressure testing the system with water, it is very important to make sure that the pump basket and lid is 
completely secure. 

Recommended Wire Sizes

Distance from Sub-panel

0 - 50 Feet

50 - 100 Feet

100 - 150 Feet

Voltage

115 / 230 VAC

115 / 230 VAC

115 / 230 VAC

Minimum Wire Size (AWG)

12 / 14

10 / 12

8 / 10

Summary of Contents for 1.1 THP Dual Voltage Series

Page 1: ...Installation Operation and Service Manual 1 1 THP Dual Voltage Series Variable Speed Pool Pump Motor Version 2 0 02 2019...

Page 2: ...Bayberry Road Jacksonville FL 32256 USA Hours Monday Friday 8 00 am to 5 00 pm EST Toll Free 800 223 8538 Phone 904 739 2626 Fax 904 737 5261 Website www usa speck pumps com Email technical usa speck...

Page 3: ...ks 9 Pressure Testing 9 4 Operation 10 Start Up guide 10 Enter Programming Mode 11 Schedule SCHE Menu 12 Override OVRD Menu 13 Priming PR Menu 13 Normal Operation 14 User Interface Lockout 15 5 Servic...

Page 4: ...ult circuit interrupter GFCI Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI The unit must be connected only to a supply circuit that is protected by a...

Page 5: ...rapment If not a single unblockable outlet in the event of one suction outlet being completely blocked the remaining suction outlets serving the system shall have a flow rating capable of the full flo...

Page 6: ...level for your application These variable speed pumps are designed to meet the needs of today s more environmentally friendly consumer The pump parts are made of 100 recyclable environment friendly p...

Page 7: ...tenance 4 Install the pump in a well ventilated location protected from direct sunlight and excessive moisture rain sprinklers etc 5 Protect the pump against flooding and excess moisture and prevent f...

Page 8: ...nded that thread seal tape be used Hard plumbed pipes must have proper solvent weld connections Flexible hose connections must be tightened properly If the suction line is not sealed correctly the pum...

Page 9: ...er performance and long motor life Incorrect voltage will cause the error light to turn on and cause damage to the motor if not turned off immediately It is the responsibility of the electrical instal...

Page 10: ...starting this procedure 1 Release all pressure from the system and open the filter pressure release valve 2 Depending on the location of the pump do one of the following 4 Operation Start Up Guide If...

Page 11: ...followed check for a suction leak If there is a leak repeat Steps 2 through 6 NOTE It is normal for a few drops of water to escape from the mechanical seal from time to time This is especially true d...

Page 12: ...isplay Use the and buttons to select the desired power level Watts Press the button to save the power level and move on to the duration setting See Figure 6 1 ERROR 3 OK 2 ERROR POWER SET OK 0 3 2 1 2...

Page 13: ...eature First press the button and then the button simultaneously when the pump is running The pump will ramp up to full speed 1000 Watts for the programmed override duration At the end of the programm...

Page 14: ...ctory Default Schedule is S1 200 Watts 12 Hours S2 0 Watts 0 Hours S3 0 Watts 0 Hours Under the default schedule the pump will run at 200W for 12 hours and then remain off for 12 hours every day NOTE...

Page 15: ...ll with water up to the suction pipe Clean the clear lid o ring and sealing surface of the pump of any debris 7 Replace lid with lid ring Hand tighten the lid to make an air tight seal DO NOT use any...

Page 16: ...The pump must be protected when freezing temperatures are expected Allowing the pump to freeze will cause severe damage and void the warranty There are two options when winterizing the pump Option 1 1...

Page 17: ...tep does not clear the error code contact your pool professional for service 6 Troubleshooting Table 2 0 Figure 5 Error Code Error Description 01 DC link over voltage 02 DC link under voltage 03 DC li...

Page 18: ...the pump starts while your hand is inside the pump 1 Turn OFF the pump Switch off the circuit breaker to the pump motor If you are not replacing the motor do not disconnect the electrical wiring Probl...

Page 19: ...ing water with a small amount of dish soap brush the impeller shaft for ease of assembly 10 With the carbon side up push the mechanical onto the impeller shaft and wipe carbon surface with a clean clo...

Page 20: ...using to the pump casing strainer tank 3 Slide the motor and flange seal housing away from the casing stainer tank 4 Remove the diffuser by gently pulling the diffuser horizontally until the pins are...

Page 21: ...RPM 100 Watts 1300 1700 RPM 0 U S Gallons Per Minute 10 30 50 20 40 60 80 100 90 70 10 20 30 40 50 60 70 Total Head in Feet B A C Model E71 II VHV 1000 Watts 2650 3250 RPM 450 Watts 2000 2450 RPM 0 U...

Page 22: ...1 LID CLEAR LID CLEAR with LED LIGHT LOCK RING WITH HANDLES LID O RING LID 137 x 5mm BASKET ONE PIECE CASING DRAIN CAP 3 8 WITH GASKET CASING LEGO SPACER SCREW CASING HEX SLOT M7 x 48mm SS O RING DIFF...

Page 23: ...NG LID LID CLEAR O RING LID 105 x 5mm COMPLETE UNION PACKAGE SUCTION DISCHARGE SLIP HOSE COMPLETE UNION PACKAGE SUCTION DISCHARGE HOSE COMPLETE UNION PACKAGE SUCTION DISCHARGE SLIP COMPLETE UNION PACK...

Page 24: ...O RING LID 137 x 5mm BASKET ONE PIECE O RING CASING 144 x 4mm IMPELLER II 1 1THP 106 9mm W INSERT SCREW CASING HEX WASHER SLOT M7 x 48mm CASING DUAL DISCHARGE MECHANICAL SEAL 5 8 CARBON CERAMIC STRAIN...

Page 25: ...le for an extended warranty Only products purchased through a pool service company a pool builder or a pool store AND installed by a pool professional along with a licensed electrician are eligible fo...

Page 26: ...M THE USE OF OR INABILITY TO USE THE PUMP AND MOTOR OR THE PERFORMANCE OR NONPERFORMANCE OF ANY OBLIGATION UNDER THIS LIMITED WARRANTY THIS PARAGRAPH THE WARRANTY DISCLAIMERS IN PARAGRAPH 4 ABOVE AND...

Page 27: ...27...

Page 28: ...2999999406 Rev 0717...

Reviews: