OPERATING INSTRUCTIONS 

 

 

 

 

19 

pump,  and  the  delivery  side  to  the  seperator 

tank. Lipuid bags should be avoided. 

5.3 

Pipes 

Suction and discharge connections as well as 

the  connection  for  the  operating  liquid  are 

sealed,  when  the  pumps  is  supplied,  in  order 

to avoid the penetration of any foreign bodies. 

The  seals  are  not  to  be  removed  before  the 

pipes are fitted. 
The  internal  diametre  of  the  suction  and  dis-

charge pipe as well as the pipes for the operat-

ing liquid should not be smaller than the corre-

sponding  pump  connections  and  as  short  as 

possible.  For  longer  pipes  wider  internal  dia-

metres should be chosen. 
The pipes should be fitted to the pump without 

strain.  In  case of big temperature differences, 

a compensator in the pipe should be provided 

additionally for the suction and discharge side. 
Before  starting  the  pump  the  sealings  of  the 

pipes have to be checked carefully. 

5.3.1  Suction pipes 
In  the  suction  pipe  a  non  return  valve  should 

be mounted in order to avoid the filling of the 

vacuum pipe with the operating liquid resp. in 

order to avoid a pressure drop in the vacuum 

system. 

CAUTION

 

If a shut-off device (sliding valve or similar) is 

fitted  in  the  suction  pipe  and  if  the  pump 

should  be  commissioned,  when  this  shut-off 

device is closed, cavitation will occur. This will 

destroy  parts  of  the  pump  during  a  longer 

working period. 

5.3.2  Discharge Pipes 
If in the discharge pipe or in the discharge pipe 

of  the  liquid  separator  a  shut-off  device  is 

installed, it has to be taken care that the pump 

will not be operated or kept running while the 

shut-off device is closed. 

5.4 

Electrical connection 

   

 

Electrical connection of the pump must be 

carried out by skilled personnel only! 
The connecting diagramm of the motors is 

shown inside the terminal box cover. 
Apart  from  the  faultless  electrical  installation 

required  (taking  into  account  appropriate  guide-

lines and VDE regulations), serious consideration 

is  necessary  of  the  pump's  direction  of  rotation 

(flow  direction),  which  is  shown  by  an  arrow  on 

the pump casing. 
The  electric  motor  always  needs  a  protective 

motor switch (except for versions with coil protec-

tion  contacts  or  posistors,  serving  for  the  direct 

motor  switch-off).  Operating  without  a  protective 

motor switch on the input side that is properly set 

(at  a  rated  current  of  IN)  shall  invalidate  any 

claims for compensation of damages. 
The  rotating  direction  of  the  shaft  as  well  as 

the  flow  direction  of  the  gas  is  marked  by 

arrows at the pump casing. 

CAUTION

 

Wrong direction of rotation leads that pump 

gets damaged! 

5.5 

Operation modes 

5.5.1  Open circulation cooling 
(standard operation under normal conditions) 
The setting up is per illustr. 3a. The operating 

liquid B consists of clean liquid F and circulat-

ing  liquid  U.  Liquid  similar  to  clean  liquid  F 

added,  leaves  the  liquid  separator  as  dis-

charge  liquid  A  through  the  liquid  discharge 
U

A

. The pressure of clean liquid should exceed  

max.  0,2  bar  the  pressure  at  the  pump  dis-

charge nozzle resp. in the liquid separator. 

5.5.2  Closed circulation cooling 
The  closed  circulation  cooling  is  applied  for 

operating  liquids,  which  have  due  to  their 

characteristics  to  remain  in  the  circulatory 

process or which may not get in touch with the 

cooling  medium,  or  where  corrosive  ,  hazard-

ous or highly combustible gases are delivered. 

The setting up is per illustr. 4a. At connection 
U

A

  a  shut-off  device  will  be  attached.  The 

operating liquid B consists of circulation liquid 
U  in  the  circulating  pipe  I

U

,  a  liquid  ring  vac-

uum  pump  P

B

  has  to  be  mounted,  if  the  vac-

uum  pump  is  running  more  than  5  minutes 

without  considerable  pressure  difference 

between suction and discharge nozzle. 
The heat exchanger W has to dissipate about 

85 % of the motor power and possibly arising 

condensation  heat.  The  heat  exchanger  W 

Summary of Contents for VZ 11 B Series

Page 1: ...H CO KG zertifiziert DIN EN ISO 9001 Betriebsanleitung Operating Instructions Mode d emploi Fl ssigkeitsring Vakuumpumpen Liquid Ring Vacuum Pumps Pompes vide anneau liquide VZ 110B VZ 180B VZ 110G VZ...

Page 2: ...nzip 5 5 Aufstellung Einbau 5 5 1 Aufstellungsort 5 5 2 Einbau 5 5 3 Leitungen 6 5 3 1 Saugleitung 6 5 3 2 Druckleitung 6 5 4 Elektrischer Anschluss 6 5 5 Betriebsarten 7 5 5 1 Offene Umlaufk hlung 7...

Page 3: ...lnbetriebnahme vom Monteur sowie dem zust ndigen Fachpersonal Betrei ber zu lesen und muss st ndig am Einsatzort der Pumpe Anlage verf gbar sein Es sind nicht nur die unter diesem Hauptpunkt Si cherh...

Page 4: ...siehe z B Vorschriften des VDE und der rtlichen Energieversorgungsunter nehmen 2 6 Sicherheitshinweise f r War tungs Inspektions und Monta gearbeiten Der Betreiber hat daf r zu sorgen dass alle Wartu...

Page 5: ...ne pulsation sarme Verdichtung Eine kontinuierliche Zuf hrung bzw K hlung der Betriebsfl ssigkeit im Normalfall Wasser ist erforderlich Sie f hrt die entstehende Ver dichtungsw rme ab und erg nzt die...

Page 6: ...me zu pr fen 5 3 1 Saugleitung In der Saugleitung sollte ein R ckschlagventil eingebaut werden um das F llen der Vakuum leitung mit der Ringfl ssigkeit bzw um Druck abfall im Vakuum System zu vermeide...

Page 7: ...it kein Wert gelegt wird Der Aufbau erfolgt nach Abb 5a Der An schluss UU wird verschlossen Die Betriebs fl ssigkeit B besteht aus Frischfl ssigkeit F Der erforderliche Frischfl ssigkeitsdruck soll 0...

Page 8: ...turf hler zu rF2 UA Fl ssigkeitsablauf UB Anschluss f r Betriebsfl ssigkeit UN Anschluss f r Kontrollventil US Saugleitungsanschluss DU Druckleitungsanschluss UU Anschluss f r Umlauffl ssigkeit Ue Ent...

Page 9: ...BETRIEBSANLEITUNG 9 Durchlaufk hlung Abb 4a nebenst Fl ssikeitsabscheider Abb 4b Fl ssigkeits Aufbauabscheider Beh lter mit Schwimmerventil Abb 4c nebenst Fl ssigkeitsabscheider...

Page 10: ...BETRIEBSANLEITUNG 10 Geschlossene Umlauflaufk hlung Abb 5a nebenstehender Fl ssigkeitsabscheider Abb 5b Fl ssigkeits Aufbauabscheider Abb 6 Lage des Betriebswasseranschlusses...

Page 11: ...s ue3 ein Ventil angeschlossen werden Ein automatisches Entleerungsventil an diesem Anschluss kontrolliert und reguliert den Fl ssigkeitsstand selbstt tig 6 3 3 Durchlaufk hlung nach Abb 4 Bei laufend...

Page 12: ...eingestellt werden dass das gew nschte Saugverm gen bzw der gew nschte Volu menstrom erreicht jedoch Kavitation verhin dert wird Das Regulierventil ist in dieser Ein stellung zu blockieren Bei Vakuumb...

Page 13: ...d ebenso des Saugverm gens eintritt siehe 7 2 Temperatur der Fl ssigkeit durch geeig nete Ma nahmen senken Gas bzw Fl ssigkeitskan le verschlossen Pumpe zerlegen und besonders die Kan le reinigen Glei...

Page 14: ...2200 Gaseintrittstemperatur trocken 160 C wasserdampfges ttigt 80 C VZ 110 180 Drehzahl min 1 50Hz 60 Hz 1450 1750 Betriebsfl ssigkeit Temperatur 10 C 60 C Dichte 1200 kg m3 Viskosit t 4 mm2 s berdruc...

Page 15: ...stallation 18 5 2 Installation 18 5 3 Pipes 19 5 3 1 Suction pipes 19 5 3 2 Discharge Pipes 19 5 4 Electrical connection 19 5 5 Operation modes 19 5 5 1 Open circulation cooling 19 5 5 2 Closed circul...

Page 16: ...mp s place of opera tion at all times You should not just consider the general safety information listed in this point specific safety information is also con tained in the other main points 2 1 Marki...

Page 17: ...ts who are adequately informed having thor oughly read these operating instructions Basically the pump must have stopped before carrying out any work on it The procedures described in the operating in...

Page 18: ...Installation CAUTION The non observation of all safety informa tions given under 5 Setting up Installation shall invalidate any claims of warranty including claims for compensa tion of damages 5 1 Pla...

Page 19: ...faultless electrical installation required taking into account appropriate guide lines and VDE regulations serious consideration is necessary of the pump s direction of rotation flow direction which i...

Page 20: ...p will be provided with a gas ejector pump 5 6 Setting up of the unit A side mounted liquid separator has to be installed thus that the liquid discharge is at the same level as the shaft The liquid se...

Page 21: ...PERATING INSTRUCTIONS 21 Setting up schema Open circulating cooling illustr 3a side mounted separator illustr 3b top mounted separator Illustr 3c thermostatically controlled process liquid temperature...

Page 22: ...OPERATING INSTRUCTIONS 22 Continuous cooling Illustr 4a side mounted separator Illustr 4b top mounted separator Tank with float valve fitted Illustr 5a side mounted separator...

Page 23: ...OPERATING INSTRUCTIONS 23 Closed circulation cooling Illustr 5a side mounted separator Illustr 4b top mounted separator Illustr 6 position of service liquid connection...

Page 24: ...e connection Ue3 An automatic draining valve at this connection controles and regulates the liquid level auto matically 6 3 3 Continuous cooling according to illustr 5a Open shut off valve VF while th...

Page 25: ...ty resp a reduced volume flow however gives the possibility of safing fresh water resp cooling liquid at open resp closed circulation cooling Such liquid quantity should be regulated by the regulating...

Page 26: ...ozzle IG elevated by 300 mm or through a connecting pipe with nozzle to the liquid separator a The use of a gas ejector also avoids cavitation If a large amount of dirt is deposited it should be remov...

Page 27: ...e 7 2 Reduce the temperature by suitable means gas resp liquid channels are closed disassembly the pump and especially clean the channels mechanical seal is leaking change mechanical seal pump does no...

Page 28: ...200 compression pressure mbar 2500 2200 2200 gas entry temperature r dry vapour saturated 160 C 80 C speed min 1 VZ 110 180 50Hz 60 Hz 1450 1750 service liquid temperature 10 C 60 C density 1200 kg m3...

Page 29: ...2 Mise en Place 32 5 3 Tuyauteries 33 5 3 1 Tubulure d aspiration 33 5 3 2 Tubulure de refoulement 33 5 4 Branchement lectrique 33 5 5 Modes de fonctionnement 34 5 5 1 R frig ration par circulation ou...

Page 30: ...e monteur et le personnel sp cialis l exploitant avant le montage et la mise en service et qu il soit toujours disponible sur le lieu de la pompe de l installation En plus des r gles de s curit mentio...

Page 31: ...ue doit tre exclu pour les d tails consulter les prescriptions sp cifiques du pays ainsi que celles des usines d lectricit locales 2 6 Instructions de s curiti pour l entretien inspection et travaux d...

Page 32: ...cr un effet de compression impulsions r duites Il est necessaire d alimenter resp refrig rer continuellement le liquide de service norma lement de l eau Il dissipe la chaleur de com pression cr e et...

Page 33: ...un clapet anti retour devrait tre install afin d viter que la conduite vide se rempli avec liquide de service resp afin d viter une chute de pression dans le syst me vide S il y a un organe d arr t va...

Page 34: ...disponible en quantit suffisante et que l on n attache pas d int r t au recyclage du liquide de fonctionnement Si le gaz et le liquide ne doivent pas obligatoi rement tre vacu s s par ment on peut ren...

Page 35: ...rin age UL Raccord pour robinet d a ration Sch ma d installation Refroidissement par circulation en circuit ouvert Fig 3a S parateur mont s par ment Fig 3b S parateur rapport Fig 3c R gulation thermo...

Page 36: ...MODE D EMPLOI 36 Refroidissement en circuit ouvert Fig 4a S parateur mont s par ment Fig 4b S parateur rapport Fig 4c R servoir avec robinet flotteur...

Page 37: ...MODE D EMPLOI 37 Refroidissement par circulation en circuit ferm Fig 5a S parateur mont s par ment Fig 5b S parateur rapport Fig 6 Emplacement du raccord d eau de fonctionnement...

Page 38: ...e d arr t VK est ouverte Arr ter les robinets de r glage dans leur position Afin de contr ler le niveau de liquide N on peut raccorder une vanne au raccord Ue3 Une vanne de vidange automatique dans ce...

Page 39: ...ique indiqu dans les prospectus et catalogues est obtenu pour une temp rature d eau de fonc tionnement de 15 C Un fonctionnement une temp rature d eau de fonctionnement plus lev e se traduit par une r...

Page 40: ...u par le raccord de protection de cavitation une petite quantit de gaz qui ne condense pas la compression Ceci peut s effectuer par un robinet d a ration h une conduite remontant d environ 300 mm avec...

Page 41: ...onter la pompe et nettoyer les canalisations Garniture m canique non tanche Remplacer la garniture m canique La pompe n atteint pas le vide voulu pression d bit D bit d eau d coulement A trop petit V...

Page 42: ...de compression mbar 2500 2200 2200 temp rature d aspiration du gaz sec 160 C satur en vapeur d eau 80 C VZ 110 180 vitesse de rotation min 1 50Hz 60 Hz 1450 1750 anneau liquide temp rature 10 C 60 C p...

Page 43: ...billes 330 Lagertr ger Bearing housing Corps paliers 360 1 2 Lagerdeckel Earing cover Convercle de roulement 411 1 3 Dichtring Joint ring Garniture d tanch it 412 O Ring o ring Joint torique 441 Geh...

Page 44: ...MODE D EMPLOI 44 VZ B...

Page 45: ...MODE D EMPLOI 45 VZ G...

Page 46: ...MODE D EMPLOI 46...

Page 47: ...MODE D EMPLOI 47...

Page 48: ...05 Adresse SPECK PUMPEN Walter Speck GmbH CO KG Regensburger Ring 6 8 D 91154 Roth Tel 49 09171 809 0 Fax 49 09171 809 10 e mail info speck pumps d internet http www speck pumps de Vervielf ltigung je...

Reviews: