![Speck pumpen CSY Series Operating Instructions Manual Download Page 94](http://html.mh-extra.com/html/speck-pumpen/csy-series/csy-series_operating-instructions-manual_1341805094.webp)
Operating
Instructions
36
1096.0833 | CY, CSY, LNY, LSY, NPY, PY, Y, YS Series
05/2011
10.1.7 Dimension & cross-sectional drawing Y-/YS-2051
Fig. 15 Dimension drawing of Y-/YS -2051
Type
Size
50 Hz
60 Hz
Connections
Weight
~
[1/min]
[kW]
[HP]
[1/min]
[kW]
[HP]
G
S
G
D
U
e
*
[kg]
[lbs]
Y-2051 top/top
63
1~
2800
0.35
0.47
3400
0.35
0.47
G 1/2
G 1/2
G 1/8
6.2
13.7
YS-2051 top/top
3~
2800
0.50
0.67
3400
0.50
0.67
Y-2051 ax/top
63
1~
2800
0.35
0.47
3400
0.35
0.47
G 1
G 1/2
G 1/8
6.2
13.7
3~
2800
0.50
0.67
3400
0.50
0.67
Tab. 40 Data of Y-/YS-2051
1
) flat terminal box
2
) high terminal box
Weight depending on size, power, material and version
Y-2051 normal priming / YS-2051 self-priming
3~ three-phase motor / 1~ AC motor
U
e
* = Drainage (screw plug) upon request
Fig. 16 Cross-sectional drawing of Y-/YS-2051
No.
Designation
047
Mechanical seal
101
Casing
230
Impeller
411*
Sealing ring
412
O-ring
441
Shaft sealing casing
507
Splash ring
550/.1
Washer
901
Hexagon head screw
903*
Screw plug
932
Locking ring
940
Fitting key
* upon request
Tab. 41 Parts list of Y-/YS-2051