![Speck pumpen CSY Series Operating Instructions Manual Download Page 107](http://html.mh-extra.com/html/speck-pumpen/csy-series/csy-series_operating-instructions-manual_1341805107.webp)
Operating
Instructions
05/2011
1096.0833 | CY, CSY, LNY, LSY, NPY, PY, Y, YS Series
49
10.1.20 Characteristic curves CSY-4081
Fig. 35 Characteristic curves of CSY-4081
Test conditions:
The characteristic curves apply to the delivery of water with a temperature of 20°C at nominal speed. Total head and flow rate have a
tolerance range of ± 10 %, whereas the power requirement may deviate by + 10 %. Deviating properties of the media to be pumped
affect the characteristic curves.